Quick Links

Isolation
Galvanic isolators for analogue and digital
signals as well as HART
®
signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Displays
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume, weight, etc. Feature linearisation, scaling, and
difference measurement functions for programming via
PReset software.
Ex barriers
Interfaces for analogue and digital signals
as well as HART
®
signals between sensors / I/P convert-
ers / frequency signals and control systems in Ex zone 0,
1 & 2. Feature options such as mathematical functions
and 2 wire transmitter interfaces.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specifi c to universal transmitters.
Backplane
Flexible motherboard solutions for sys-
tem 5000 modules. Our backplane range features fl exible
8 and 16 module solutions with confi guration via PReplan
8470 – a PC program with drop-down menus.
5 2 0 3 B
E x S o l e n o i d /
A l a r m D r i v e r
N o . 5 2 0 3 B V 1 0 4 - I N ( 0 3 2 4 )
F r o m s e r . n o . 9 9 0 3 0 0 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 15
UK
Page 29
FR
Seite 43
DE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5203B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PR electronics 5203B

  • Page 1 Isolation Galvanic isolators for analogue and digital signals as well as HART ® signals. A wide product range with both loop-powered and universal isolators featuring linearisation, inversion, and scaling of output signals. Displays Programmable displays with a wide se- lection of inputs and outputs for display of temperature, volume, weight, etc.
  • Page 2: Table Of Contents

    Ex VENTIL- / ALARMDRIVER PRepower 5203B Indholdsfortegnelse Advarsler ................Sikkerhedsregler..............Overensstemmelseserklæring ..........Adskillelse af SYSTEM 5000..........Anvendelse................. Teknisk karakteristik ............Montage / installation............Applikationer ..............Bestillingsskema..............Elektriske specifikationer ........... DIP-switchprogrammering ..........10 Ex-data ................11 Tilslutninger ................ 12 Blokdiagram ............... 13...
  • Page 3: Sikkerhedsregler

    Reparation af modulet og udskiftning af sikringer må kun MODTAGELSE OG UDPAKNING: foretages af PR electronics A/S. Udpak modulet uden at beskadige dette, og sørg for, at manualen altid følger modulet og er tilgængelig. Indpakningen bør følge modulet, indtil dette er mon- teret på...
  • Page 4: Overensstemmelseserklæring

    Hvis der er tvivl om modulets rette håndtering, skal der rettes henvendelse til PR electronics A/S den lokale forhandler eller alternativt direkte til: Lerbakken 10 PR electronics A/S, Lerbakken 10, 8410 Rønde, Danmark tlf: +45 86 37 26 77. DK-8410 Rønde Installation og tilslutning af modulet skal følge landets gældende regler for hermed at følgende produkt:...
  • Page 5: Adskillelse Af System 5000

    ADSKILLELSE AF SYSTEM 5000 Ex VENTIL- / ALARMDRIVER PRepower 5203B Husk først at demontere tilslutningsklemmerne med farlig spænding. 1- eller 2-kanals version Billede 1: 3- / 5-port 3,75 kVAC galvanisk isolation Modulet frigøres fra DIN-skinnen ved at løfte i den nederste lås.
  • Page 6: Elektriske Specifikationer

    Elektriske specifikationer: Specifikationsområde: (@: -20°C til +60°C) Fælles specifikationer: Forsyningsspænding universel....24...230 VAC ±10% 50...60 Hz 24...250 VDC ±20% Egetforbrug ..........≤ 2 W (2 kanaler) Max. forbrug..........≤ 4 W (2 kanaler) Sikring ............400 mA T / 250 VAC Isolationsspænding, test / drift ....
  • Page 7: Dip-Switchprogrammering

    Tæthedsgrad (kabinet / klemmer) ....IP50 / IP20 Vægt ............230 g Indgange: NPN og mekanisk kontakt: Trig-niveau LOW.......... ≤ 4,0 VDC Trig-niveau HIGH ......... ≥ 7,0 VDC Max. ekstern spænding ......28 VDC Indgangsimpedans........3,48 kΩ PNP: Trig-niveau LOW.......... ≤ 4,0 V Trig-niveau HIGH .........
  • Page 9 Ex SOLENOID / ALARM DRIVER PRepower 5203B Table of contents Warnings ................16 Safety instructions.............. 17 Declaration of Conformity ..........19 How to dismantle SYSTEM 5000........20 Application ................. 21 Technical characteristics ............ 21 Mounting / installation............21 Applications................ 22 Order ..................
  • Page 10: Warnings

    Repair of the module and replacement of circuit breakers Check at the receipt of the module whether the type corresponds to the one must be done by PR electronics A/S only. ordered. WARNING!
  • Page 11: Declaration Of Conformity

    To the extent the instructions in this manual are not strictly observed, the custo- Ex certificate: 99 ATEX 126257 mer cannot advance a demand against PR electronics A/S that would otherwise Notified body for CENELEC/ATEX: UL International Demko A/S 0539 exist according to the concluded sales agreement.
  • Page 12: How To Dismantle System 5000

    HOW TO DISMANTLE SYSTEM 5000 Ex SOLENOID / ALARM DRIVER PRepower 5203B First, remember to demount the connectors with hazardous voltages. 1- or 2-channel version Picture 1: 3- / 5-port 3.75 kVAC galvanic isolation By lifting the bottom lock, the module is detached from the DIN rail.
  • Page 13: Electrical Specifications

    Valve Digital input Supply Digital input Supply Electrical specifications: Specifications range: (@: -20°C to +60°C) Common specifications: Acoustic alarm Supply voltage universal ......24...230 VAC ±10% 50...60 Hz Digital 24...250 VDC ±20% input Internal consumption ........≤ 2 W (2 channels) Max.
  • Page 14: Dipswitch Programming

    Tightness (enclosure / terminals) ....IP50 / IP20 Weight ............230 g Inputs: NPN and mechanical switch: Trig level LOW ..........≤ 4.0 VDC Trig level HIGH ..........≥ 7.0 VDC Max. external voltage........28 VDC Input impedance ......... 3.48 kΩ PNP: Trig level LOW ..........
  • Page 16 COMMANDE Ex - VANNE OU ALARME PRepower 5203B SOMMAIRE Avertissements ..............30 Consignes de sécurité ............31 Déclaration de conformité..........33 Démontage du SYSTEME 5000......... 34 Applications................ 35 Caractéristiques techniques ..........35 Montage / installation............35 Applications................ 36 Référence ................37 Spécifications électriques ..........
  • Page 17: Avertissements

    à proximité du module. De même, il est recommandé de conserver Seule PR electronics SARL est autorisée à réparer le module l’emballage du module tant que ce dernier n’est pas définitivement monté. A la et à...
  • Page 18: Déclaration De Conformité

    PR electronics SARL, Zac du Chêne, Activillage, 2, allée des Sorbiers, PR electronics A/S F-69500 Bron (tél.: (0) 472 140 607) ou à PR electronics A/S, Lerbakken 10, Lerbakken 10 DK-8410 Rønde, Danemark (tél. : +45 86 37 26 77).
  • Page 19: Démontage Du Systeme 5000

    DEMONTAGE DU SYSTEME 5000 COMMANDE Ex - VANNE OU ALARME PRepower 5203B Tout d’abord, n’oubliez pas de démonter les connecteurs où règnent des tensi- ons dangereuses. Une ou deux voies Figure 1 : Commande Ex pour vannes, voyants et alarmes Débloquez le verrou inférieur pour...
  • Page 20: Spécifications Électriques

    Vanne Entrée digitale Alimen- tation Voyant Entrée digitale Alimen- tation Spécifications électriques : Plage des spécifications : (@: -20°C à +60°C) Spécifications communes : Alarme sonore Tension d’alimentation multi-tension ..24...230 Vca ±10% 50...60 Hz Entrée 24...250 Vcc ±20% digitale Consommation interne........
  • Page 21: Configuration Des Commutateurs

    Etanchéité (boîtier / bornier)......IP50 / IP20 Poids ............230 g Entrées : NPN et contact : Niveau de déclenchement BAS ....≤ 4,0 Vcc Niveau de déclenchement HAUT....≥ 7,0 Vcc Tension externe max........28 Vcc Impédance d’entrée ........3,48 kΩ PNP : Niveau de déclenchement BAS ....
  • Page 23 Ex-VENTIL / ALARMTREIBER PRepower 5203B Inhaltsverzeichnis Warnung ................44 Sicherheitsregeln..............45 Konformitätserklärung............47 Zerlegung des Systems 5000 ..........48 Verwendung................ 49 Technische Merkmale............49 Montage / Installation............49 Anwendungen ..............50 Bestellangaben..............51 Elektrische Daten ............... 51 DIP-Schalter Programmierung ........... 52 Ex-Daten................
  • Page 24: Warnung

    Reparaturen des Moduls und Austausch von Sicherungen EMPFANG UND AUSPACKEN: dürfen nur von PR electronics A/S vorgenommen werden. Packen Sie das Modul aus, ohne es zu beschädigen und sorgen Sie dafür, dass das Handbuch stets in der Nähe des Moduls und zugänglich ist.
  • Page 25: Konformitätserklärung

    PR electronics GmbH, Bamlerstraße 92, D-45141 Essen, (Tel.: (0) DK-8410 Rønde 201 860 6660) oder mit PR electronics A/S, Lerbakken 10, DK-8410 Rønde, hiermit für das folgende Produkt: Dänemark (Tel. : +45 86 37 26 77) Kontakt aufnehmen.
  • Page 26: Zerlegung Des Systems 5000

    ZERLEGUNG DES SYSTEMS 5000 Ex-VENTIL / ALARMTREIBER PRepower 5203B Zunächst ist gefährliche Spannung von den Anschlussklemmen zu trennen. 1- oder 2-Kanal-Ausführung Abbildung 1: 3 / 5 Port 3,75 kVAC galvanische Isolation Das Modul wird von der DIN- Schiene gelöst, indem man den Ventiltreiber für Ex-Bereich...
  • Page 27: Elektrische Daten

    Elektrische Daten: Umgebungstemperatur: (@: -20°C bis +60°C) Allgemeine Daten: Versorgungsspannung universelles..... 24...230 VAC ±10% 50...60 Hz 24...250 VDC ±20% Eigenverbrauch ........... ≤ 2 W (2 Kanäle) Max. Verbrauch ........... ≤ 4 W (2 Kanäle) Sicherung ............ 400 mA T / 250 VAC Isolationsspannung Test / Betrieb....
  • Page 28: Dip-Schalter Programmierung

    Schutzart (Gehäuse / Klemme) ....IP50 / IP20 Gewicht ............230 g Eingänge: NPN und mechanischer Kontakt: Trig-Niveau LOW ......... ≤ 4,0 VDC Trig-Niveau HIGH ........≥ 7,0 VDC Max. externe Spannung......28 VDC Eingangsimpedanz ........3,48 KΩ PNP: Trig-Niveau LOW ......... ≤ 4,0 V Trig-Niveau HIGH ........
  • Page 30 Head offi ce PR electronics A/S tilbyder et bredt program af analoge og di- Denmark www.prelectronics.com gitale signalbehandlingsmoduler til industriel automation. Vores PR electronics A/S sales@prelectronics.dk Lerbakken 10 tel. +45 86 37 26 77 kompetenceområder omfatter: Isolation, Displays, Ex-barrierer, DK-8410 Rønde fax +45 86 37 30 85 Temperatur samt Backplanes.