Safety Labels And Their Locations - KING RH Series Installation Manual

Overhead short wave electric infrared heater
Table of Contents

Advertisement

SW2
Series

Safety Labels and Their Locations

It is important to provide warnings to alert individuals to potential hazards and safety actions. Signs
should state the hazards for the particular application and be legible to the building occupants. Consult
the factory or a factory representative for additional information on signage compliance.
Safety warning labels must be maintained on the infrared heater. Illustrations of the safety labels and
their locations are pictured below. When no longer legible, they must be replaced. Contact either your
local distributor or the product manufacturer for obtaining replacement signs or labels.
FIRE HAZARD. Always maintain published clearances to
combustibles. In locations used for the storage of combustible
materials, signs must be posted.
DANGER D'INCENDIE. Toujours maintenir un dégagement
publié à combustibles. Dans les endroits utilisés pour le stockage
de matériaux combustibles, panneaux doivent être installés.
CLEARANCES TO COMBUSTIBLES - Inches (Millimeters)
Mounting
Side
Length
Angle
Front
Behind
Short Wave/High-Output Medium Wave Single Element
24"
16 (407)
16 (407)
33"
45°
47 (1194)
4 (102)
46"
Short Wave/High-Output Medium Wave Double Element
24"
28 (712)
28 (712)
33"
45°
86 (2185)
4 (102)
46"
Short Wave/High-Output Medium Wave Triple Element
24"
31 (788)
31 (788)
33"
45°
105 (2667)
4 (102)
46"
Heaters mounted on an angle between 0° and 45° must maintain clearances posted for 0° or 45°, whichever is greater.
F/N: LLECL001a - Clearances to Combustibles Label
WARNING
Avoid Serious Injury, Death, or Property Damage.
Maintain Clearances to Combustible to Prevent the Risk of Fire.
Clearances to combustibles must be maintained at
all times in order to prevent the ignition of
combustible materials. In locations used for the
storage of combustible materials, signs must be
posted to specify the maximum permissible stacking height to
maintain the required clearances from the heater to the
combustibles. Signs must either be posted adjacent to the
heater's thermostats or, in the absence of such thermostats, in a
conspicuous location. Clearances are provided on the heater's
safety label and in the heater's Installation, Operation, and
Maintenance manual. Product installation and operation must
comply with applicable standards, codes, and regulations. Post
this tag adjacent to the heater's thermostat or controls before
operating the heater.
- INSTALLER: READ AND POST THIS NOTICE -
F/N: LL001 - Clearance Safety Tag
(Affix adjacent to heater's controller)
SHOCK HAZARD. Disconnect all
supplies before working on any
circuit.
RISQUE D'ÉLECTROCUTION. Débrancher
toutes les alimentations avant d'exécuter des
travaux sur un circuit quelconque.
Heater MUST be properly
grounded prior to operation.
End
Top
Below
HOT. Do not touch any part of
the heater while in operation.
12 (305)
6 (153)
56 (1423)
Read and understand the installation, operating, and maintenance
12 (305)
10 (254)
40 (1016)
instructions thoroughly before installing or servicing this equipment. Failure
to properly apply product may result in property damage, injury, or death.
26 (661)
6 (153)
86 (2185)
26 (661)
10 (254)
86 (2185)
34 (864)
9 (229)
105 (2667)
End
34 (864)
10 (254)
105 (2667)
END VIEW - 0°
California Proposition 65
!
This product can
expose you to
chemicals including
lead and carbon
monoxide, which are known to the
State of California to cause birth
defects or other reproductive harm.
For more information go to
www.P65Warnings.ca.gov.
LL001-XM-07/18 (CDS)
1.0
Safety
Top View
F/N: LLECL004
Caution Label
AVOID EQUIPMENT
FAILURE. Use 10AWG
supply wires suitable for
105°C or equivalent.
ÉVITEZ LES PANNES
D'ÉQUIPEMENT. Employer
10AWG des fils d'alimentation
adéquats pour 105°C.
Apply proper voltage.
Top
Top
Behind
End
Side
Side
Below
Below
SIDE VIEW - 0°
END VIEW - 45°
LLECL001a-xM-11/18 (CDS)
MODEL NO.
SW-33S3-G25R
VOLTAGE
480 VAC
AMPERES (FLA)
15.63
TOTAL WATTAGE
7500
DETROIT RADIANT PRODUCTS COMPANY
21400 HOOVER ROAD - WARREN, MI
(586) 756-0950
7
Safety Labels and Their Locations
L1
LAMP NO. 1
L2
LAMP NO. 2
NOTE: USE COPPER CONDUCTORS ONLY
ATTENTION: UTILISER DES CONDUCTEURS EN CUIVRE
(Located inside the raceway)
Front
ELECTRIC INFRARED HEATER
INFRAROUGE A CHAUFFE AU ELECTRIQUE
SERIAL NUMBER
VERSION
1702DETRXXXXXX 0001
FREQUENCY
PHASE
MINIMUM MOUNTING HEIGHT
50/60 Hz
Single or Three
MIN. MOUNTING ANGLE
REPLACEMENT LAMP(S):
STANDARD
ALTERNATE
EL - 086A
076A
THIS DESIGN COMPLIES WITH STANDARD(S):
MAX. MOUNTING ANGLE
UL 2021 - Edition 3 (revision 2013)
CSA C22.2 #46 (revision 2013)
FOR COMMERCIAL, INDUSTRIAL, AND OUTDOOR RESIDENTIAL USE.
FOR INDOOR OR OUTDOOR USE.
-
www.drp-co.com
MADE IN USA.
Rating Plate
CAUTION
- VERIFY SUPPLY VOLTAGE -
-VÉRIFIEZ LA TENSION D'ALIMENTATION-
DISCONNECT FROM ELECTRICAL SUPPLY
BEFORE SERVICING THIS HEATER.
DÉBRANCHEZ DE L'ALIMENTATION ÉLECTRIQUE
AVANT L'ENTRETIEN DE CET APPAREIL DE CHAUFFAGE.
THIS APPLIANCE MUST BE PROPERLY
GROUNDED TO THE ELECTRICAL SOURCE.
CET APPAREIL DOIT ÊTRE CORRECTEMENT
MIS À LA TERRE À LA SOURCE ÉLECTRIQUE.
Electrical Label