KING RH Series Installation Manual page 6

Overhead short wave electric infrared heater
Table of Contents

Advertisement

1.0
Safety
Clearances to Combustibles
Chart 1.3
Clearances to Combustibles in Inches (Millimeters) - see Figure 1.1
Mounting
Length
Angle
Single Element
24''
33''
46''
45°
Double Element
24''
33''
45°
46''
Triple Element
24''
33''
46''
45°
* Heaters mounted on an angle between 0° and 45° must maintain clearances posted for 0° or 45°,
whichever is greater.
NOTE: Ensure that building materials with a low heat tolerance (i.e, awnings, fabrics, plastics, sprinklers,
insulation, etc.) are protected against degradation. This may require the heater to be mounted at a
distance in excess of the published clearances to combustibles. Contact the material manufacturer for
specific details.
Figure 1.1
Clearances to Combustibles
TOP
SIDE
BELOW
END VIEW
0° Mounting Angle
Side
Front
16 (407)
47 (1194)
28 (712)
86 (2185)
31 (788)
105 (2667)
END
0° Mounting Angle
SIDE
Behind
End
16 (407)
12 (305)
4 (102)
12 (305)
28 (712)
26 (661)
4 (102)
26 (661)
31 (788)
34 (864)
4 (102)
34 (864)
TOP VIEW
6
SW2
Top
Below
6 (153)
56 (1423)
10 (254)
40 (1016)
6 (153)
86 (2185)
10 (254)
86 (2185)
9 (229)
105 (2667)
10 (254)
105 (2667)
END
TOP
BEHIND
BELOW
END VIEW
45° Mounting Angle
Series
FRONT

Advertisement

Table of Contents
loading

Related Products for KING RH Series

This manual is also suitable for:

Rsh1215Rh-33b1-c25w

Table of Contents