Philips Lumea BRI959 Manual page 26

Hide thumbs Also See for Lumea BRI959:
Table of Contents

Advertisement

Technical specifications
Rated voltage
Rated frequency
Rated input
Protection against electric shock
Protections rating
Operating conditions
Storage conditions temperature
Storage conditions humidity
Maximum variation of the light
output over the treatment area
Operating pressure
Duration of the pulsetrain
Emitted wavelengths
Lithium-ion battery
Optical exposure
Maximum optical energy
Optical homogeneity
Repetition time
Pulse duration
Flash interval
Pulse sequence
Optical spectrum
Troubleshooting
Problem
The device/adapter
becomes warm during use.
BRI959, BRI956, BRI954, BRI953, BRI950
100V-240V
50Hz-60Hz
65W
Class II
IP 30 (EN 60529)
Temperature: 5 °C to 35 °C
Relative humidity: 15% to 90% (non condensing)
-25° to +70°C
Less than 90% (non condensing)
< 0%
2
700hPa-1060hPa
Single pulse
565 to 1400 nm
2 x 3.6 Volt 1000 mAh
2.4-6.5 J/cm2
4.8 - 23 J
Max. +/- 0% deviation from average optical exposure in
2
treatment area
1-3.5 s
<2.5 ms
Between 1-3.5s depending on battery/mains connected use
Single pulse
560-1200 nm
Possible cause
It is normal for the device and
adapter to become warm (but
not too hot to touch) during
use.
Solution
Use the device in a slightly cooler
environment and/ or let it cool down
before continuing use.
27
English

Advertisement

Table of Contents
loading