Settings And Operation; Dmx 512 Connection; Fixture Cleaning - Beamz LED Par36 DMX 9x1W RGB Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

SETTINGS AND OPERATION

DMX-512 CONNECTION
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the
first unit in a DMX chain. Always connect the output of one unit with the input of the next unit until all units are connected.
If you use a controller with 5 pin DMX connection you will need to use a 5-pin to 3-pin adapter.
DMX signal
At the last fixture, the DMX cable has to be terminated. Solder a 120 Ohm resistor between signal (-) and signal (+)
into a 3-pin XLR connector and plug this into the DMX output of the last fixture in the chain.

FIXTURE CLEANING

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding
can cause greater accumulation of dirt on the unit's optics.
Make sure the area below the installation place is free from unwanted persons during servicing
Housings, fixations and installations spots( ceiling, truss, suspensions) should be totally free from any deformation
The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is
detected
In order to protect the fixture from overheat the cooling fans (if any) and ventilation openings should be cleaned
monthly.
The interior of the fixture should be cleaned annually using a vacuum cleaner or air-jet.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every month. Clean the internal optics at least every 30/60 days.
ATTENTION: We strongly recommend internal cleaning to be carried out by qualified worker!
4
Press "Menu" to switch into the Menu.
Mode setting
Axxx = DMX control
ATxx = Auto/Sound mode
Edxx = Auto mode
Slav = Slave mode
Load = Reset to factory defaults
Press "UP" and "DOWN" button to choose, press "ENTER" to select.
DMX address setting
When display shows "Axxx" you can set the DMX start address.
Press "UP" or "Down" to adjust the value (001 – 512), press "ENTER" to save the
address setting.

Advertisement

Table of Contents
loading

This manual is also suitable for:

151.155

Table of Contents