7. TROUBLESHOOTING
7.2.4 Troubleshooting: Real time status indications
Access to AT-commands
Instead of using the PC hyperterminal facility, access can easily accomplished
using vtLite Mobile.
Verify MPDS status: key in at + wreg =1 to register.
Note: For access to all advanced status indications, enable traffic log.
Read information
MPDS status:
inactive
allocating
tuning
tuned
registering
registered
connected
deregistering
reregister_chan - the terminal was told to regregister to a new channel
reregister_les
handover
failed
deregistered
7-14
SBS
COM1
key in at + wreg =0 to deregister.
- MPDS is not active
- internal pre processing
- terminal is tuning to the LESP
- the terminal is tuned to the LESP and awaits a
registration possibility
- the terminal has sent one or more registration bursts
- the terminal has successfully registered with MPDS
- CONNECT has been received from the dialled host
- the terminal awaits deregister ack
- the terminal was told to regregister with a new LES
- the terminal is following a handover instruction
- the last operation failed
- the terminal has successfully deregistered and is set
to normal mode.