Installation Instructions
Gas connection
1.
Remove the shipping cap from gas pipe at
the rear of the dryer.
IMPORTANT
DO NOT connect the dryer to L.P. gas service
without converting the gas valve. An L.P. con-
version kit must be installed by a qualified gas
technician.
2. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid
or approved pipe from gas supply line to the
3/8 inch (0.96 cm) pipe located on the back
of the dryer. Use a 1/2 inch to 3/8 inch (1.27
cm to 0.96 cm) reducer for the connection.
Apply an approved thread sealer that is
resistant to the corrosive action of liquefied
gases on all pipe connections.
Manual
Shutoff
Valve
Open
Closed
All connections must be wrench-tightened
Flare
GAS FLOW
Flare
Union
Union
Nipple
Flexible
Inlet Pipe on
Connector
Back of Dryer
3. Open the shutoff valve in the gas supply line
to allow gas to flow through the pipe. Wait
a few minutes for gas to move through the
gas line.
Shuto Valve -
Open position
4. Check for gas system leaks with a
manometer. If a manometer is not available,
test all connections by brushing on a soapy
water solution.
WARNING
EXPLOSION HAZARD
NEVER test for gas leaks with an open flame.
IMPORTANT
Installation to the gas service must follow local
codes and ordinances and the latest edition of
the National Fuel Gas Code ANSI Z223.1/NEPA
54 or in Canada, CSA B149.1.