Technical data

Unusual noises
Problem
Loud humming
13
Technical data
ACDC models:
DC models:
Refrigerator compartment storage
volume:
Freezer compartment storage
volume:
Total storage volume:
Voltage:
Power consumption (AC)
(ACDC models only):
Rated current
12 Vg:
24 Vg:
100 Vw (ACDC models only):
240 Vw (ACDC models only):
Cooling temperature range
Refrigerator:
Freezer:
Fast cooling (without dividing wall):
36
Possible cause
A component of the refrigerant circuit
cannot move freely (touching the
wall)
There is a foreign object stuck
between the cooling unit and the wall
Fan noise
CRX50
CRX1050
CRX0050
41.2 l
(1.45 cu.ft.)
4.4 l
(0.16 cu.ft.)
45 l
(1.59 cu.ft.)
100 – 240 Vw (ACDC models only)
40 W
5.0 A
2.6 A
1.14 A
0.53 A
maximum –6 °C (21 °F) ± 2 °C (36 °F)
Remedy
Bend the component
carefully away from the
obstruction
Remove the foreign
object
Replace the fan
CRX65
CRX1065
CRX0065
50 l
(1.77 cu.ft.)
7.0 l
(0.25 cu.ft.)
57 l
(2.01 cu.ft.)
12 Vg or 24 Vg
45 W
5.5 A
2.8 A
1.22 A
0.58 A
+3 °C (37 °F) to +12 °C (54 °F)
–15 °C (5 °F) to –5 °C (23 °F)
CRX
CRX80
CRX1080
CRX0080
70.6 l
(2.49 cu.ft.)
7.5 l
(0.26 cu.ft.)
78 l
(2.75 cu.ft.)
48 W
5.6 A
2.9 A
1.23 A
0.56 A