Burner - Zanussi ZGNN955X User Manual

Hide thumbs Also See for ZGNN955X:
Table of Contents

Advertisement

The connection should be suitable for connecting
to R 1/2 (1/2 BSP male thread).
When the final connection has been made, it is
essential that a thorough leak test is carried out on
the hob and installation.
Make sure that the main connection pipe does not
exert any strain on the hob.
If you use flexible metal pipes make sure that they
agree to ISO 10380 and ISO 10807 standards. Be
careful they do not come in touch with mobile parts
or they are not squeezed. Also be careful when the
hob is put together with an oven.
CAUTION! It is important to install the
elbow correctly, with the shoulder on
the end of the thread, fitted to the hob
connecting pipe.
CAUTION! Failure to ensure the
correct assembly will cause leakage of
gas.
CAUTION! Make sure that the gas
supply pressure of the appliance
obeys the recommended values.
Rigid connection:
Carry out connection by using metal rigid pipes
(copper with mechanical end).
INJECTORS REPLACEMENT
1. Remove the pan supports.
2. Remove the caps and crowns of the burner.
3. With a socket spanner 7 remove the injectors
and replace them with the ones which are
necessary for the type of gas you use (see
table in "Technical Data" chapter).
4. Assemble the parts, follow the same procedure
backwards.
5. Attach the label with the new type of gas
supply near the gas supply pipe. You can find
this label in the package supplied with the
appliance.
If the supply gas pressure is changeable or
different from the necessary pressure, you must fit
an applicable pressure adjuster on the gas supply
pipe.
ADJUSTMENT OF MINIMUM LEVEL
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob and the gasket.
WARNING! Pay attention not to
damage the gasket. Do not use sharp
tool to remove it.
4. With a thin screwdriver, adjust the bypass
screw position (A).
A
5. If you change:
from natural gas G20 20 mbar to liquid gas,
fully tighten the bypass screw in.
from liquid gas to natural gas G20 20 mbar,
undo the bypass screw approximately 1/4
of a turn (1/2 of a turn for Multi Crown

burner).

6. Reassemble the gasket and the knob.