Interface - Panasonic AJSD930P Operating Instructions Manual

Hide thumbs Also See for AJSD930P:
Table of Contents

Advertisement

Setup menus
USER menu
<INTERFACE>
No./Item
200
This selects whether two or more VTRs are to
be operated in synchronization.
PARA RUN
0000
DIS : No operation in synchronization
0001
ENA : Operation in synchronization
<Note>
When
operating
synchronization, set all the VTRs to ENA.
201
This selects whether the REMOTE (9P)
connector functions when the CONTROL
9P SEL
switch has been set to REMOTE.
0000
OFF : Connector does not function.
0001
ON : Connector functions.
202
This sets the ID information to be returned to
the controller.
ID SEL
0000 OTHER
0001 DVCPRO
0002
ORIG
<Notes>
OID information of any VTR except for the
DVCPRO's is set in OTHER.
OThe ORIG setting should only be used when a
Panasonic controller (AG-A850 etc. sold
separately) is connected.
203
This selects whether the PARALLEL (25P)
connector functions when the CONTROL
25P SEL
switch has been set to REMOTE.
0000
OFF : Connector does not function.
0001
ON : Connector functions.
204
This selects whether the RS-232C connector
functions when the CONTROL switch has
RS232C SEL
been set to REMOTE.
0000
OFF : Connector does not function.
0001
ON : Connector functions.
205
These settings are for selecting the RS-232C
communication speed (baud rate).
BAUD RATE
0000
300
0001
600
0002
1200
0003
2400
0004
4800
0005
9600
206
These settings are for selecting the RS-232C
data length. (Unit: bit)
DATA
LENGTH
0000
0001
207
These settings are for selecting the RS-232C
stop bit length. (Unit: bit)
STOP BIT
0000
0001
The underlined items indicates the initial setting.
Description
two
or
more
VTRs
7
8
1
2
No./Item
208
These settings are for selecting the none, odd
or even for the RS-232C parity bit.
PARITY
0000
Parity bit is not used.
0001
in
An odd number of bits is used for the parity
system.
0002
An even number of bits is used for the parity
system.
209
These settings are for selecting whether the
ACK code is to be returned when a command
RETURN ACK
is received from RS-232C.
0000
0001
210
For selecting the method used to detect the
STANDBY COMMAND signal input at the
25P STBY
PARALLEL (25P) connector.
CMD
0000 OFF/ON :
Each time active signals are detected, the
STANDBY ON or STANDBY OFF mode is
selected alternately.
0001
When active signals are detected in the
STANDBY OFF mode, the unit is transferred to
the STANDBY ON mode.
Nothing happens if they are detected during an
operation in the STANDBY ON mode.
211
This selects whether the PARALLEL (25P)
connector is to function when the CONTROL
LOCAL 25P
switch is at the LOCAL position.
0000
0001
212
SD955A
For selecting the remote control connector to
control the slave when the unit is used as the
MASTER
master during deck-to-deck operations.
PORT
0000 IN/OUT : The IN/OUT connector is used.
0001
<Note>
This menu item takes effect only when the
CONTROL switch has been set to the LOCAL
position.
Description
NON :
ODD:
EVEN:
OFF : ACK code is not returned.
ON : ACK code is returned.
ON :
OFF : Connector does not function.
ON : Connector functions.
OUT : The OUT connector is used.
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ajsd955ap

Table of Contents