Interface Menu - Panasonic AJ-HD1500P Operating Instructions Manual

Dvcpro digital hd video cassette recorder
Table of Contents

Advertisement

Setup menus
USER menu
<INTERFACE>
No.
200
201
202
203
204
205
206
207
208
209
211
The underline on the setting item denotes the initial setting.
Item
Setting
Superimposed
Superimposed
No.
display
display
PARA RUN
0000
0001
9P SEL
0000
0001
ID SEL
0000
0001
DVCPRO
0002
50P SEL
0000
0001
RS232C SEL
0000
0001
BAUD RATE
0000
0001
0002
0003
0004
0005
DATA
0000
LENGTH
0001
STOP BIT
0000
0001
PARITY
0000
0001
0002
RETURN
0000
ACK
0001
LOCAL 50P
0000
0001
– 80 –
This selects whether two or more VTRs are to be operated in
DIS
synchronization.
ENA
0: No operation in synchronization
1: Operation in synchronization
<Note>
When operating two or more VTRs in synchronization, set all
the VTRs to 0001 (ENA). (See pages 9 and 17.)
This selects whether the 9P connector functions when the
OFF
REMOTE/LOCAL switch has been set to REMOTE.
ON
0: Do not function
1: Function
OTHER
This selects the ID information which is returned to the
controller.
0: OTHER
ORIG
1: DVCPRO
2: ORIG
<Note>
1. The ID information of a VTR other than a DVCPRO format
VTR is selected for "0 (OTHER)."
2. Select "2 (ORIG)" only when the unit has been connected
to a specific controller made by Panasonic (such as the AJ-
A900, available as an optional accessory).
OFF
This selects whether the PARALLEL (50P) connector functions
ON
when the REMOTE/LOCAL switch has been set to REMOTE.
0: Does not function
1: Functions
These settings are for selecting whether the RS-232C
OFF
connector is to function when the REMOTE/LOCAL switch is
ON
set to REMOTE.
0: Connector does not function.
1: Connector functions.
300
These settings are for selecting the RS-232C communication
600
speed (baud rate).
1200
2400
4800
9600
7
These settings are for selecting the RS-232C data length.
8
(Unit: bit)
1
These settings are for selecting the RS-232C stop bit length.
(Unit: bit)
2
These settings are for selecting the none, odd or even for the
NON
RS-232C parity bit.
ODD
0: Parity bit is not used.
EVEN
1: An odd number of bits is used for the parity system.
2: An even number of bits is used for the parity system.
OFF
These settings are for selecting whether the ACK code is to be
ON
returned when a command is received from RS-232C.
0: ACK code is not returned.
1: ACK code is returned.
This selects whether the PARALLEL (50P) connector is to
OFF
work when the REMOTE/LOCAL switch has been set to
ON
LOCAL.
0: The connector does not work.
1: The connector works.
Description