VOLTCRAFT VC611BT Operating Instructions Manual page 53

Hide thumbs Also See for VC611BT:
Table of Contents

Advertisement

Available languages

Available languages

Fuse replacement
Disconnect the product from the power source before opening the power
compartment.
Disconnect the measuring leads from the product before opening the power
compartment.
Never operate the meter when it is open. Danger to life!
Turn the two screws on top of the product from the position "CLOSE" to "OPEN" to unlock the power
compartment.
The fuse compartment is secured with an additional screw. Remove the Phillips screw from the lid of
the fuse compartment. Remove the lid.
Replace the broken fuse with a new one of the same type. See the chapter technical data.
Close the fuse compartment and turn the two screws on top of the product from the position "OPEN"
to "CLOSE" to lock the power compartment.
In addition to the fuses (for the measuring leads) in the fuse compartment, there is a mains fuse next
to the mains inlet (16).
Proceed as follows to replace the mains fuse:
1. Remove all the connection cables and the mains plug from the device.
2. Lever the mains fuse from the bracket using a suitable screwdriver.
53