FMI C36EMW-RBC-LS Owners & Installation Manual

36" circulating louvered firebox

Advertisement

Quick Links

36" CIRCULATING LOUVERED
FIREBOX
OWNER'S INSTALLATION
MANUAL
C36EMW-RBC-LS with Black Finish
Bi-fold Doors
C36EMW-RPLC-LS with Platinum
Finish Bi-fold Doors
PFS
Includes Manual
®
Control Fan System
C
US
and Combustion
Air Kit
SAVE THIS BOOK
This book is valuable. In addition to instructing you
f i r e - p a r t s . c o m
on how to install and maintain your appliance, it also
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep
it with your other important papers.
This fireplace is approved for use as a wood burning
fireplace or for use with a vented gas log approved to
ANS Z21.60 or Z21.84 standards or for use with a vent-
free gas log heater approved to ANS Z21.11.2 standard.
A vent-free log can only be installed in an aftermarket
(completion of sale, not for purpose of resale from the
manufacturer), permanently located, manufactured
(mobile) home, where not prohibited by local codes. Ap-
proved hood must be installed when using a vent-free
gas log heater (see Accessories, page 18).
This firebox meets the construction and safety stan-
dards of H.U.D. for application in mobile homes when
installed according to these instructions.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C36EMW-RBC-LS and is the answer not in the manual?

Questions and answers

Summary of Contents for FMI C36EMW-RBC-LS

  • Page 1 36" CIRCULATING LOUVERED FIREBOX OWNER’S INSTALLATION MANUAL C36EMW-RBC-LS with Black Finish Bi-fold Doors C36EMW-RPLC-LS with Platinum Finish Bi-fold Doors Includes Manual ® Control Fan System and Combustion Air Kit SAVE THIS BOOK This book is valuable. In addition to instructing you f i r e - p a r t s .
  • Page 2: Table Of Contents

    • Never leave children unat- • The FMI PRODUCTS, LLC warranty will tended when a fire is burning be voided by and FMI PRODUCTS, LLC in the fireplace. disclaims any responsibility for the follow- ing actions. This fireplace is not intended to a.
  • Page 3: Specifications

    SPECIFICATIONS Round Top Termination Storm Collar Flashing Firestop 42" Thimble " " " " 13" Firestop " 5/8" 1" Airspace To Combustible 36" 3" Materials 41" 1" Combustible Wall Board 0" To Top Spacer 1/2" Air Space Back and Sides No Combustible J-Box Material On Face...
  • Page 4 FIREPLACE INSTALLATION Continued Maximum height of any system is 40 feet.* " This measurement includes fireplace, chim- 10" ney sections and height of termination assem- bly at level of flue gas outlet (see Figure 3). *For manufactured home application, minimum height is 11' for straight flue or flue with one elbow "...
  • Page 5 FIREPLACE INSTALLATION Continued FRAMING HEARTH EXTENSION A hearth extension projecting a minimum of 1. Frame opening for fireplace using dimen- 16" in front of and a minimum of 8" beyond sions shown in Figures 1 and 2. each side of the fireplace opening is required 2.
  • Page 6: Venting Installation

    FIREPLACE INSTALLATION Continued FAN KIT ASSEMBLY (BK2) 5. Secure electrical cover plate with screws previously removed. A fan kit assembly is preinstalled in this 6. Tighten strain relief plastic screw fireplace. Use of blowers or fans other than model BK2 voids warranty. Fan is operated by Note: Electrical housing and cover plate have pressing rocker switch located at lower right sharp edges.
  • Page 7 VENTING INSTALLATION Continued Insert Inner Tab of Inlet Tube into Slot Insulation Air Vent Location on Outer Surround Must Allow for Bushes, Snow and Other Possible Obstructions Left Side Mounting Shown Secure to Collar with Outside Metal Tape, Screws or Air Vent Tie Straps Termination...
  • Page 8 VENTING INSTALLATION Continued ADJUSTABLE FIRESTOP THIMBLE There are two vent kits available which have been specially designed for common installa- (FST-A) tions in manufactured (mobile) homes: MW8K Adjustable Firestop Thimble Assembly (FST-A) (8' vent kit) and MW9K (9' vent kit). Contents is used to provide necessary air space and of these kits are listed under Accessories on clearance between chimney pipe and insula-...
  • Page 9 VENTING INSTALLATION Continued PENETRATING ROOF If adapter is needed, secure it onto firestop us- ing holes provided (see Figure 12). The row of To maintain a 1" clearance to pipe on a roof holes on sides of thimble is provided to allow with a pitch, a rectangular opening must be for pitch variances.
  • Page 10 VENTING INSTALLATION Continued USING ELBOW OFFSETS (30E-8DM) 2. Chimney weight above offset rests on return elbow. Straps must be securely 1. To achieve desired offset, you may install nailed to rafters or joists (see Figure 15, combinations of 12", 18", 24", 36" and 48" details A and B).
  • Page 11 VENTING INSTALLATION Continued Return Return Return Offset Elbow Offset Elbow Elbow Elbow Elbow 6' Max. 6' Max. Ceiling Support Pipe Return 12S-8DM Return 6' Max. Elbow Elbow 6' Max. Offset Offset Elbow 6' Max. Elbow 6' Max. Offset Elbow Figure 16 - Typical Offset Terminations (For Systems with 2 Elbow Sets, Maximum Height is 20') FIRESTOP SPACERS (3600FS-8DM) Storm Collar...
  • Page 12 VENTING INSTALLATION Continued RTL-8DM Attach Storm Collar Installation (SC1) Bracket Tabs Place storm collar over pipe and slide down Level of to Outer Pipe until it is snug against the open edge of flash- Flue Gas (3 Places) ing (see Figure 19). Use SC1 for all round Outlet Secure with terminations.
  • Page 13: Optional Gas Line Installation

    VENTING INSTALLATION Continued 10 FOOT RULE must not penetrate inner flue pipe). The angle of support wires should not be more than 45° All flue gas outlet chimney terminations must from horizontal when fastened to roof. Place extend a minimum of 3 feet in height above the chimney support brackets approximately 18"...
  • Page 14 VENTING INSTALLATION Continued 3. Run a 1/2" black iron gas line into fireplace Note: Secure incoming gas line to wood fram- through rear at gas line conduit sleeve ing to provide rigidity for threaded end. (if using a raised platform, add height). If you wish to install an unvented (vent- Provide sufficient gas line into fireplace free) gas log set, ONLY UNVENTED GAS...
  • Page 15: Finishing Fireplace

    FINISHING FIREPLACE Combustible materials, such as wallboard, Note: HUD requirements may supersede gypsum board, sheet rock, drywall, plywood, these minimum dimensions. etc. may make direct contact with sides and Combustible top around the fireplace face. It is important that Material "...
  • Page 16 OPERATION AND MAINTENANCE GUIDELINES Continued Door Removal 1. Fold doors (fully open) and press up on upper door spring clip until top pin is free of the spring clip (see Figure 28). Tip door toward middle of fireplace opening and lift door out of the lower pivot hole.
  • Page 17: Technical Service

    If this product is missing a part or has a installation, operation, or troubleshooting. broken component, please do not return it If so, contact FMI PRODUCTS, LLC at to the store. Call FMI PRODUCTS, LLC at 1-866-328-4537. 1-866-328-4537 to answer questions and replace parts under warranty.
  • Page 18: Parts

    PARTS OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION 90154 - Model AK6E BRICK LINER Rear - PN 20029 Left Side - PN 20030 Right Side - PN 20030 Front Bottom - PN 21242 DUAL FAN KIT - BK2 Rear Bottom - PN 21241 GRATE - 11116 f i r e - p a r t s .
  • Page 19 ACCESSORIES Continued 12"/96" Pitch 12" 7.13" 96" 30"/144" Pitch 30" 11.77" 144" ADJUSTABLE HOOD GA6053 - Antique Brass Finish GA6050 - Black Painted Finish This hood is required when installing a vent- free gas log heater in this firebox. ADJUSTABLE FIRESTOP THIMBLE FST-A Includes: Thimble - PN 22383...