FMI CCAT36 Series Owner's Operation And Installation Manual

FMI CCAT36 Series Owner's Operation And Installation Manual

Catalytic 36'' wood burning fireplace

Advertisement

Quick Links

PFS
C
FMI CATALYTIC FIREPLACE CCAT36 SERIES
These models meet the EPA Wood Burning Fireplace
Program Phase 2 emission level. NOTE: To ensure proper
fireplace operation, the catalyst should be replaced at a
minimum of 3 years and a maximum of 5 years.
This book is valuable. In addition to instructing you
on how to install and maintain your appliance, it also
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep
it with your other important papers.
This fireplace is approved for use as a wood burning fire-
place or for use with a vented gas log approved to ANS
Z21.60 and Z21.84 standards or for use with a vent-free gas
log heater approved to ANS Z21.11.2 standard. A FMI PROD-
UCTS, LLC hood must be installed when using a vent-free
log heater (see Accessories, page 21).
This wood burning fireplace complies with UL127-
CAN/ULC-S610-M87 standard as a FACTORY BUILT
APPLIANCE.
FOR CANADA: The authority having jurisdiction (such
as the municipal building department, fire department,
etc.) should be contacted before installation to deter-
mine the need to obtain a permit.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com
CATALYTIC FIREPLACE OWNER'S
OPERATION AND INSTALLATION MANUAL
®
US
36" WOOD BURNING FIREPLACE
SAVE THIS BOOK

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CCAT36 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FMI CCAT36 Series

  • Page 1 ANS Z21.60 and Z21.84 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. A FMI PROD- UCTS, LLC hood must be installed when using a vent-free log heater (see Accessories, page 21).
  • Page 2: Table Of Contents

    Before beginning installation of this fireplace, • Due to high temperatures, the read these instructions through completely. appliance should be located • This FMI PRODUCTS, LLC fireplace and out of traffic and away from its components are safe when installed furniture and draperies.
  • Page 3: Specifications

    SPECIFICATIONS GAS LINE RIGHT SIDE KNOCK ELECTRICAL OUTS OUTLET 1" AIRSPACE TO COMBUSTIBLE MATERIAL 0" TO 9.125" NO COMBUSTIBLE 3.5" MATERIAL ON FACE SPACERS 7.092" 8.717" AIR KIT 11.217" KNOCK OUT LEFT SIDE GAS LINE KNOCK COMBUSTIBLE OUTS WALL BOARD 0.75"...
  • Page 4: Fireplace Installation

    FIREPLACE INSTALLATION SELECTING LOCATION 3. Set fireplace directly in front of this open- ing and slide unit back until nailing flanges To determine safest and most efficient location touch side framing. for fireplace, you must take into consideration 4. Check level of fireplace and shim with the following guidelines: sheet metal if necessary.
  • Page 5 FIREPLACE INSTALLATION HEARTH EXTENSION Seal Gap Fireplace Front A hearth extension projecting a minimum of 16" in front of and a minimum of 8" beyond each side of fireplace opening is required to Ember Protector protect combustible floor construction in front of fireplace.
  • Page 6: Venting Installation

    CHIMNEY PIPE space (AK4F) or through a sidewall (AK4). FMI PRODUCTS, LLC chimney system See Figure 23 on page 15 for instruction of consists of 12", 18", 24", 36" and 48" snap- operating air kit.
  • Page 7 VENTING INSTALLATION Continued Secure to Collars with Metal Tape, Screws " or Straps (Min. of 1/4" x 20" in size) Galvanized Outer Pipe Air Inlet Hemmed Location Must Allow 8" Stainless For Bushes Inner Pipe or Snow LINEAL GAIN PART NO. DESCRIPTION GAIN Air Inlet...
  • Page 8 VENTING INSTALLATION Continued Continue to assemble chimney sections as 2. Chimney weight above offset rests on outlined, making sure that both inner and return elbow. Straps must be securely outer pipe sections are locked together. When nailed to rafters or joists (see Figure 9, installing double wall snap-lock chimney to- details A and B on page 9).
  • Page 9 VENTING INSTALLATION Continued See Detail A Ceiling Support Pipe 12S-8DM 2" Min. See Detail B Straps Straps Straps Straps Detail A Detail B Return Elbow Angle Firestop Figure 9 - Ceiling Support Pipe 12S-8DM OFFSET RISE CHIMNEY LENGTH 48" 36" 24" 18" 12" "...
  • Page 10 VENTING INSTALLATION Continued FIRESTOP SPACERS (3600FS-8DM-1) 4. Remove shingles around opening mea- sured. Cut out this section. Firestop spacers are required at each point 5. Add next sections of pipe until end where chimney penetrates a floor space. penetrates roof line. Check to see that Their purpose is to establish and maintain proper clearances are maintained.
  • Page 11 VENTING INSTALLATION Continued Terminations with 16" slip pipe sections are Overlap Storm Collar Shingles Top available. RTT-8DM and RTTL-8DM are Flashing and Sides Only approved for flashing installations. When Cone needed, these adjustable terminations may Nail Only be used in combination with pipe assembly Outer to achieve correct chimney height.
  • Page 12 VENTING INSTALLATION Continued 10 FOOT RULE FINISHING THE FIREPLACE All flue gas outlet chimney terminations must Combustible materials, such as wallboard, extend a minimum of 3 feet in height above gypsum board, sheet rock, drywall, plywood, highest point where it passes through roof and etc.
  • Page 13: Purefire Installation

    PUREFIRE HOOD INSTALLATION 1. The PureFire hood supplied with this fire- Hood Refractory place is packaged in a separate box and Retainer placed in the firebox during shipping. 2. Remove hood from box. 3. Lift the hood up into the fireplace at an angle with the rear facing up.
  • Page 14: Operation And Maintenance

    WARNING: If the fireplace PERSON. has been used for wood burn- ing, firebox and chimney must Note: A FMI PRODUCTS, LLC hood must be be cleaned of soot, creosote and installed when using an unvented gas log set ashes be a qualified chimney (see Accessories on page 21).
  • Page 15 Pushing handle in will lock door closed. WARNING: Risk of fire! Re- place grate with FMI PRODUCTS, Doors Fully Closed LLC model 125186-01 only. This grate has been designed to keep...
  • Page 16: Hearthcatâ„¢Emissions Control System

    * EPA has determined, based on testing by an accredited independent laboratory and a certification of conformity by a nationally recognized certification body, that this model qualifies at the Phase 2 cardboard or salt driftwood. emissions level for U.S. EPA's Voluntary Fireplace Program. Refer to your FMI PRODUCTS, LLC Home- www.fmiproducts.com 125183-01B...
  • Page 17 8 to 10 minutes of operation while the fire manufacturer. is dissipating. Under normal operating condi- Neither FMI PRODUCTS, LLC nor the dealer tions, you should see little or no smoke coming who sells the PureFire Emissions Control out of the chimney. If continuous smoke is...
  • Page 18: Parts

    PARTS WOOD BURNING FIREPLACE MODELS (V)CCAT36, (V)CCAT36I, (V)CCAT36H, (V)CCAT36L, (V)CCAT36LI, (V)CCAT36LH 36/37 40/41 38/39 www.fmiproducts.com 125183-01B...
  • Page 19 PARTS WOOD BURNING FIREPLACE MODELS (V)CCAT36, (V)CCAT36I, (V)CCAT36H, (V)CCAT36L, (V)CCAT36LI, (V)CCAT36LH This list contains replaceable parts used in your fireplace. When ordering parts, see Replace- ment Parts on page 21 of this manual. NO. PART NO. DESCRIPTION (V)CCAT36(I,H) (V)CCAT36L(I,H) QTY. 106638-01 Insulation Pan •...
  • Page 20: Replacement Parts

    You may have further questions about You can also visit our web site at installation, operation, or troubleshooting. www.fmiproducts.com. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready.
  • Page 21: Accessories

    ACCESSORIES DOUBLE WALL PIPE 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT ANTI-DRAFT SHIELD (Round Top Termination Only) ADS-8DM 30° OFFSET AND RETURN 30E-8DM ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM ROUND TOP TERMINATIONS RT-8DM, RTL-8DM FIRESTOP SPACER...
  • Page 22 ACCESSORIES Continued OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION - AK4 BI-FOLD GLASS DOOR BD36 - Black BD36B - Brushed Brass BD36P - Platinum OUTSIDE AIR KIT FOR FLOOR INSTALLATION ADJUSTABLE HOOD AK4F Antique Brass Finish - GA6053 Black Painted Finish - GA6050 Required when installing a vent-free gas log in this fireplace.
  • Page 23: Notes

    NOTES _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ www.fmiproducts.com 125183-01B...
  • Page 24 2701 S. Harbor Blvd. Santa Ana, CA 92704 125183-01 1-866-328-4537 Rev. B www.fmiproducts.com 12/10...

Table of Contents