Control Codes - Samsung SBB-SS08EL1/EN User Manual

Table of Contents

Advertisement

Control Codes

Viewing control state (Get control command)
Header
Command
ID
0xAA
Command type
Controlling (Set control command)
Header
Command
ID
0xAA
Command type
Command
No.
Command type
1
Power control
2
Volume control
3
Input source control
4
PIP on/off control
5
Safety Lock
• All communications take place in hexadecimals. The checksum is calculated by adding up all
values except the header. If a checksum adds up to be more than 2 digits as shown below
(11+FF+01+01=112), the first digit is removed.
E.g. Power On & ID=0
Data length
Checksum
0
Data length
Data
1
Value
Command
Value range
0x11
0~1
0x12
0~100
0x14
-
0x3C
0~1
0x5D
0~1
Header
Command
0xAA
0x11
Header
Command
0xAA
0x11
• To control all devices connected by a serial cable simultaneously irrespective of IDs, set the ID as
"0xFE" and transmit commands. Commands will be executed by each device but ACK will not
respond.
Checksum
ID
Data length
Data 1
1
"Power"
ID
Data length
Data 1
1
1
Checksum
12
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sbb-ss08e

Table of Contents