Water Dispenser - Electrolux ICON Designer E23BC78ISS Use And Care Manual

French door bottom freezer/refrigerator
Hide thumbs Also See for ICON Designer E23BC78ISS:
Table of Contents

Advertisement

Temperatures Are Too Warm (continued)
Problem
Cause
Refrigerator temperature
Refrigerator control is set too warm.
is too warm. Freezer
temperature is
satisfactory.
Temperature in the
Temperature control is set too warm.
Deli Drawer or Custom
Temp
Drawer is too
TM
warm (select models).

Water Dispenser

Problem
Cause
Dispenser will not dispense
Water supply is not connected.
water.
Household water line valve is not open.
Ice & water filter cartridge is clogged.
Water has an odd taste
Water has been in the tank for a period of time.
and/or odor.
Unit not properly connected to cold water line.
Tubing used in the household water supply and
installation may affect water taste and odor.
Water has a high mineral content.
Water pressure is
Cut-off and cut-on pressures are too low (well
extremely low.
systems only).
Reverse osmosis system is in regenerative phase.
Water/Moisture/Frost Inside Refrigerator
Problem
Cause
Moisture collects on
Weather is hot and humid.
inside of refrigerator
walls.
Door is slightly open.
Door is opened too often or too long.
Open containers.
Water collects on bottom
Vegetables contain and give off moisture.
side of drawer cover.
Moisture collects in
Washed vegetables and fruit drain while in
bottom of drawer.
the drawer.
Fruits and vegetables are kept past their
prime
Moisture collects on
Weather is humid.
outside of refrigerator or
between doors.
Door is slightly open, causing cold air from
inside refrigerator to meet warm air from
outside.
Solutions to Common Problems
Correction
Set refrigerator control to a colder setting. Allow 24
hours for temperature to stabilize.
Adjust temperature control to a colder setting.
Correction
Connect water supply (see Connecting The Water Supply
section).
Open household water line valve. See Problem section Ice
Maker Is Not Making Ice.
Replace filter cartridge being sure to remove protective caps.
Draw and discard 10-12 glasses of water to freshen the
supply and completely rinse out the tank.
Connect unit to cold water line that supplies water to the
kitchen faucet.
For best results, use copper tubing for water connections.
Contact water treatment plant for help in checking water
supply source.
Have someone turn up the cut-off and cut-on pressure on
the water pump system (well systems only).
It is normal for a reverse osmosis system to be below 20 psi
during the regenerative phase.
Correction
The rate of frost buildup and internal sweating
increases.
See Problem section, Opening/Closing of Doors/
Drawers.
Open door less often to allow internal temperature to
stabilize.
Keep containers covered.
Moisture on the bottom side of the cover is not unusual.
Move humidity control (select models) to lower setting.
Dry items before putting them in the drawer. Water
collecting in bottom of drawer is normal.
Routinely clean out old fruits and vegetables especially if
they begin to break down.
This is normal in humid weather. When humidity is
lower, the moisture should disappear.
See Problem section, Opening/Closing of Doors/
Drawers.
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

E23bc78ips - 22.6 cu.ft

Table of Contents