Power Source ...............................................................................................................................................120 V, 60 Hz
Power Consumption ......................................................................................................................................... 132 Watts
Fan Output ........................................................................................................................................................ 212 CFM
Treatment Process ........................................................................... Carbon filter & twin hydroxyl and ozone chambers
UV Lamp Type ................................................................................................................... UVC 254 nm germicidal lamp
Reaction Surface .............................................................................................. 266.90 Square Inches, 25,000 Hour Life
Room Capacity .....................................................................................................................................2500 Square Feet
Dimensions .......................................................................................................................8.2 (W) x 10 (D) x 17 (L) inches
Weight .................................................................................................................................................................... 11Lbs
Ozone Output ..........................................................................................................................................................1GPH
UV Lamps not functioning.
• The life of the UV bulb may have been met or damaged. If they are burnt out, replace both bulbs as shown on pages 10
to 12. If broken, refer to pages 4 and 5 for Handling and Disposal of Mercury.
• Fuse has blown. Unplug and turn over unit to access fuse. Rotate fuse holder and replace with 2 Amp fuse.
• Internal Component failure; call 1-866-676-9663 for service.
Generator is not performing well.
• The life of the carbon filter may have been met or damaged; replace both carbon filters, see page 9.
• The life of the UV bulb may have been met or damaged. If they are burnt out, replace both bulbs as shown on pages 10
to 12. If broken, refer to pages 4-5 for Handling and Disposal of Mercury.
• Internal Component failure; call 1 - 866 - 676 - 9663 for service.
Generator not working at all
• Unit is not plugged in, or power is not active at the AC socket.
• 2 Amp Fuse has blown. Unplug and turn over unit to access fuse. Rotate fuse holder and replace with 2 Amp fuse.
• 1 Amp Fuse has blown. Unplug and turn over unit to access fuse. Rotate fuse holder and replace with 1 Amp fuse.
• Timer time is up. Press the Power switch to the OFF position and then to the TIMER or ON position.
• If Ozone is not working, make sure the Power switch is set to the TIMER position, the HYDROXYL TIMER knob is set and
finally, make sure the OZONE TIMER knob is set.