Electronic Parts Troubleshooting Guide - LG TM-1830C2L Svc Manual

Multi type room air conditioner
Table of Contents

Advertisement

Electronic Parts Troubleshooting Guide

1. Product does not operate at all.
(* Refer to Electronic Control Device drawing and Schematic diagram.)
Check the voltage of power(About AC 220V/AC240V, 60Hz)
• Main power's voltage
• Voltage applied to the unit
• Connecting method of Indoor/Outdoor connecting
cable
• Check Fuse (Outdoor PCB Ass'y)
• Check Varistor
ZNRØ1J(Outdoor PCB Ass'y)
Check the connection housing for contacting
• Connector related to CN-DC/AC
• Display PWB Ass'y Check
Items
• Power Transformer
(Outdoor unit)
- Input Voltage
- Output Voltage
• IC01D(7812) Output
(Indoor/Outdoor unit)
• IC02D(7805) Output
(Indoor/Outdoor unit)
• IC01A(KIA7036, Reset IC)
X01(8MHz)
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Turn off Main Power
Turn on Main Power
Does "beeping" sound is made from the Indoor Unit?
NO
PCB Board Operation Check
- About AC220V/240V ± 10% - Check the power voltage
- About AC14 ± 3V
• DC + 12V
• DC + 5V
• Voltage of Micom No. 2,
(DC +4.5V over) and Soldering condition.
(After 10 seconds)
Primarily, the operating condition of Micom is OK.
Check each load(Indoor/Outdoor Fan Motor,
Compressor, Stepping Motor etc.) and contacting
condition of related connector
Content
- 44 -
YES
Remedy
• Replace Trans
• Replace IC01D
• Replace IC02D
• Replace faulty parts
LGE Internal Use Only