Advertisement

http://biz.lgservice.com

Room Air Conditioner

SVC MANUAL(Exploded View)
MODEL : TS-C2425DA1
TS-C2425ML1
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TS-C2425DA1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LG TS-C2425DA1

  • Page 1: Room Air Conditioner

    Room Air Conditioner SVC MANUAL(Exploded View) MODEL : TS-C2425DA1 TS-C2425ML1 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
  • Page 2: Specification

    1. Specification Product Model TS-C2425DA1 Sales Model SJ242CD Capacity Cooling Capacity Btu/h 24000 Heating Capacity Btu/h Electrical Parts 1,220V,60Hz Voltage. Frequency/Phase Φ / V / Hz 2560 Power Input Cooling Heating 12.0 Running Current Cooling Heating Performance Cooling Btu/h 9.38...
  • Page 3: Service Manual

    1. Specification Product Model TS-C2425ML1 Sales Model SP242CM Capacity 24000 Cooling Capacity Btu/h Heating Capacity Btu/h Electrical Parts Voltage. Frequency/Phase Φ / V / Hz 1,220V,60Hz Power Input Cooling 2560 Heating Running Current Cooling 12.0 Heating Performance 9.38 Cooling Btu/h Heating 14.5 Air Circulation...
  • Page 4: Piping Diagrams

    2. Piping Diagrams Indoor Unit Outdoor Unit Capillary Tube Liquid Side 2-Way Valve Heat Heat Exchanger Exchanger (Evaporator) (Condenser) Compressor Gas Side Accumulator 3-Way Valve High Pressure S/W Cooling Thermistor for indoor air temperature CN-TH1 Thermistor for evaporating temperature (2) Cooling & Heating Models CHECK VALVE LIQUID SIDE (Heating Model only)
  • Page 5: Wiring Diagrams

    3. Wiring Diagrams Outdoor Unit TS-C2425DA1 BLUE TS-C2425ML1 CAPACITOR BLUE BLUE OVERLOAD PROTECT TERMINAL BLOCK 1(L) 2(N) THE UNIT INDOOR OUTDOOR DIAGRAM WIRING EBY36312302 Service Manual 5...
  • Page 6: Exploded View

    Exploded View Exploded View 1. Indoor Unit 135316 135301 152302 135313 135511 131410 733010 342800 149303 359011 135311 354212 354210 147581 352115 435301 346810 35211B 352116 268711C 135516 352150 147582-2 147582-1 W0CZZ W6640 264110 146811 263230 268711A 267110 249951 6 Room Air Conditioner...
  • Page 7 Exploded View Exploded View Outdoor Unit 554031 437212 552112 435512 552111 649950 549610 W0CZZ 435511 559010 430400 546810 W6640 447910 435301 554160 552203-1 550140 430410 552203-2 437210 148000 6 Room Air Conditioner...
  • Page 8 P/NO : MFL58884505 SEP, 2008...