Installation
(1) Installation of Indoor, Outdoor unit
1) Selection of the best location
1. Indoor unit
There should not be any heat source or steam
•
near the unit.
• There should not be any obstacles to prevent
the air circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from
the wall, ceiling, fence, or other obstacles.
2. Outdoor unit
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful that
heat radiation from the condenser is not
restricted.
• There should not be any animals or plants
which could be affected by hot air discharged.
• Ensure the spaces indicated by arrows from
the wall, ceiling, fence, or other obstacles.
3. Piping length and the elevation
Pipe Size
GAS
LIQUID
1/2"(3/8")
1/4"
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Max.
Max. piping
Elevation
length
B (m)
A (m)
15(590.6")
8(314.9")
- 21 -
Front
Down right
Right
Rear right
More than
5cm(2")
More than eye-level
More than 10cm(4")
More than 70cm(28")
Indoor unit
B
Left
Rear left
More than 5cm(2")
More than
5cm(2")
More than 10cm(4")
A
Outdoor unit