Mitsubishi Electric Fresh Master GUF-100RDH3 Operating Instructions Manual page 6

Hide thumbs Also See for Fresh Master GUF-100RDH3:
Table of Contents

Advertisement

Display section
D
E
F
G
H
For purposes of explanation, all the displays on this page are shown
in their lit condition. This configuration does not occur in the actual
unit.
A [Current/starting/ending time] Display
When the time switch button is pressed, the current time, starting time
and ending time are displayed for 10 seconds. During timer operation,
the next starting time or ending time is always displayed.
B [Centralized control] Display
Displayed when control is executed by a separately sold centralized con-
trol unit, etc.
C [Timer] Display
This displays the modes of continuous operation/timer operation. Time
is simultaneously displayed at the time of timer operation.
D Operation mode
Displays the status of operation.
E [Preparing for Heating] Display
Displayed from the start of heating operation until the moment warm air
blows out.
F [Defrosting] Display
Displayed during defrosting operation.
G [Checking] Display
This displays indication when an abnormality occurs in the unit.
H [Set temperature] Display
Displays the set temperature.
I [Address numbers of indoor unit/unit in linked motion] Display
Displayed when some abnormality occurs in the unit.
J [Error number] Display
Displays the (4-digit) checking code when an abnormality occurs in the
unit.
K Display "'"
Displayed while the air conditioner is powered.
6
C
B
A
CENTRALLY CONTROLLED
ON OFF
DAILY
AUTO OFF
CLOCK
REMAINDER
CHECK
STAND BY
˚C
ERROR CODE
DEFROST
TEMP.
CLOCK→ON→OFF
TIMER SET
PAR-F27MEA
I
J
K
T
W
V
U
1Hr.
˚C
FILTER
CHECK MODE
TEST RUN
LIMIT TEMP.
NOT AVAILABLE
ON/OFF
FILTER
CHECK TEST
L
M
N
L [Louver operation] Display
This displays the operation of a swing louver. This does not display in
case of stop.
M [Not available] Display
When a button is pressed for any function that the indoor unit cannot
perform, this display flashes concurrently with the display of that func-
tion.
N [Ventilation] Display *
Displayed during the Fresh Master's operation.
O [Position of built-in room temperature sensor]
P [Set effective for one hour] Display
Displays when the low air blow, downward blow, or horizontal blow (dif-
fers according to model) are set in the air-cooling and electronics dry
operation. This display disappears after the elapse of one hour.
Q [Now checking/test run] Display
R [Filter] Display
Displayed when it is time to clean the filter.
S [Sensor] Display
Shows a position of the sensor that measures the room temperature.
T [Operation] Lamp
Lights up during operation, goes off during stop, and flashes in case of
abnormality.
U [Room temperature] Display
Displays the temperature of the air sucked in during operation. The range
of display is 8° to 39°C. For temperatures outside this range, the display
flashes at 8°C and 39°C.
V [Up/down airflow direction] Display
Displays the air blowout direction with a s mark.
W [Fan speed] Display
Displays the selected fan speed.
* When interlocked only.
S
R