Programming; Program Limits - Chamberlain LiftMaster LA412 Owner's Manual

The chamberlain group, inc. 12 volt dc single solar residential gate operator owner's manual
Hide thumbs Also See for LiftMaster LA412:
Table of Contents

Advertisement

PROGRAMMING

Program Limits

The limits are internal settings that indicate when the gates are in the fully open position and the fully closed position. For
proper functionality, the limits must be programmed during the installation process. The programming uses a combination
of buttons on the control board.
The specifi c buttons used for programming depends on which side of the gate the control box is mounted and how many
operators the installation includes. Refer to pages 11 and 13 to determine if the gate is Left- or Right-handed.
If a mistake is made during programming press the RESET button on the outside of the control box to start over.
SINGLE ARM LEFT-HAND SIDE
NOTE: The programming can be exited at any time by pressing the RESET button. The programming times-out automatically after 60
seconds of inactivity.
PROGRAM OPEN
With the gate in the CLOSED position, press the LEARN
LIMITS button (SET OPEN LIMIT LED will blink).
LEARN LIMITS button
R223
OPEN EDGE/
OPEN EDGE/
K6
EDGE
CLOSE
ALARM
NO
R2Ø7
C
Z2Ø
R227
K5
GATE 1
MAGLOCK
PHOTO
NO
L1
BRN
C
R224
GRN
NC
U4
R92
Z22
R2
LEARN
ON
MAGLOCK
OFF
Z9
WHT
Z1
R1
XMITTER
OPEN
YEL
10A 32V
PHOTO
BLU
F3
R91
RED
R94
D1Ø
K2
Z8
U4
CLOSE
DIAGNOSTIC
PHOTO
R93
GATE 1
SET
SET
OVLD
COM
Z12
K1
Q9
OPEN
CLOSE
LIMITS
LEARN
CONTROL
INPUTS
SET
LIMIT
LIMIT
OPEN
ACCESSORY
POWER
R9Ø
GATE 2
RUNNING
TIMER
SINGLE BUTTON
ACCESSORY
24V
OVLD
TIMER TO
RESET
R1Ø1
FORCE
CLOSE
STOP
OPEN
BRN
COM
R1ØØ
F4
COM
GRN
10A 32V
POWER
WHT
YEL
K4
OFF
MAX
F5
LIMIT
BLU
D21
RED
K3
D9
R35
GATE 2
D8
C12
Z3
F7
Z4
C13
LOOP
INPUTS
Q22
D22
C4
SHADOW
U3
C11
INTERRUPT
D15
CHGR
COM
R4
C2
R196
F6
OVLD
SOLAR
24 VAC/
F2
F1 20A 32V
INPUT
MOV2
J4
MOV1
C64
R9
D1
D4
FUSE
JMPR2
U2
JMPR1
D2
OPEN
BATT 2
BATT 1
DB1
D4
D2
RESET
BUTTON
Press the Gate 1 right button to move gate to the desired
OPEN position. When gate is in the desired position, press
the LEARN LIMITS button again. Control board will beep.
DIAGNOSTIC
GATE 1
SET
CLOSE
PROGRAM CLOSE
Press the Gate 1 left button to move gate to the desired
CLOSED position. When gate is in the desired closed
position, press the LEARN LIMITS button again.
DIAGNOSTIC
GATE 1
SET
CLOSE
The control board beeps and the SET OPEN LIMIT and SET CLOSE LIMIT LEDs stop blinking, programming is
now complete. (If the SET OPEN LIMIT LED continues to blink, repeat programming. If the problem continues, see
Troubleshooting section.)
Test the limits by pressing the SBC to open and close the gate.
RESET
BUTTON
SINGLE ARM RIGHT-HAND SIDE
PROGRAM OPEN
With the gate in the CLOSED position, press the LEARN
LIMITS button (SET OPEN LIMIT LED will blink).
Press the Gate 1 left button to move gate to the desired
OPEN position. When gate is in the desired position, press
the LEARN LIMITS button again. Control board will beep.
DIAGNOSTIC
GATE 1
SET
CLOSE
PROGRAM CLOSE
When the SET CLOSE LIMIT LED blinks, press the
Gate 1 right button. When gate is in the desired closed
position, press the LEARN LIMITS button.
DIAGNOSTIC
GATE 1
SET
CLOSE
33
LEARN LIMITS button
SET
OFF
U4
OPEN
EN
LIMIT
T
D9
Z3
Z4
U3
D4
D1
D2
Programming
OPEN EDGE/
OPEN EDGE/
R223
K6
CLOSE
EDGE
ALARM
NO
R2Ø7
Z2 Ø
R227
C
MAGLOCK
K5
NO
PHO T O
L1
C
R224
NC
U4
Z22
R92
R2
ON
MAGLOCK
OFF
Z9
Z1
LEARN
XMITTER
OPEN
10A 32V
R1
PHO T O
GATE 1
BRN
F3
R91
D1Ø
K2
R94
GRN
Z8
WHT
CLOSE
DIAGNOSTIC
PHO T O
YEL
R93
BLU
GATE 1
RED
K1
SET
SET
LEARN
Z12
Q9
LIMIT
OPEN
CLOSE
LIMIT
LIMITS
ACCESSORY
R9Ø
GATE 2
RUNNING
TIMER
COM
POWER
OVLD
ACCESSORY
TIMER TO
CONTROL
24V
R1Ø1
OVLD
FORCE
CLOSE
INPUTS
OPEN
BRN
R1ØØ
SINGLE BUTTON
F4
GRN
10A 32V
RESET
WHT
K4
OFF
MAX
STOP
YEL
COM
BLU
F5
COM
D21
R35
POWER
RED
K3
D9
GATE 2
D8
C12
Z3
F7
LOOP
Z4
C13
C4
INPUTS
Q22
D22
SHADOW
U3
C11
INTERRUPT
D15
CHGR
COM
R4
C2
R196
OVLD
24 VAC/
F6
F2
SOLAR
F1 20A 32V
J4
INPUT
MOV2
R9
D4
MOV1
C64
D1
FUSE
BATT 2
BATT 1
JMPR2
U2
JMPR1
D2
OPEN
DB1
RESET
BUTTON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liftmaster la412-s

Table of Contents