Juniper C Series Hardware Manual page 66

Hide thumbs Also See for C Series:
Table of Contents

Advertisement

C2000 and C4000 Hardware Guide
To display the IPMI chassis information on a remote controller:
1.
2.
Viewing Power Status of a Controller Using IPMI
You can view IPMI power information for the controller you are currently logged on
to and for a remote controller. You must be logged in as a root user.
To display power status (on or off) of the local controller using IPMI:
1.
2.
3.
4.
50
Viewing Power Status of a Controller Using IPMI
Chassis Intrusion
Front-Panel Lockout
Drive Fault
Cooling/Fan Fault
Log in as root user.
Enter the
show ipmi host chassis
user@host>show ipmi host host user user chassis
host IP address of remote host IPMI interface
user IPMI username configured in the remote host
For example:
root@host>show ipmi host 10.10.10.30 user johndoe chassis
Log in as root user.
SRC-PE Release 3.1 [R.3.1.0-12]
login: root
Enter the password.
Password: password
You are now logged in as root user.
Access the CLI.
[root@host ~]# cli
--- SRC CLI 3.1 build CLI.R.3.1.0.012
(c) 2005-2008 Juniper Networks Inc.
root@host>
Enter the
show ipmi power
For example:
root@host>show ipmi power
Chassis Power is on
: inactive
: inactive
: false
: false
command.
command.