Omron 5 Series Instruction Manual

Omron 5 Series Instruction Manual

Upper arm blood pressure monitor
Hide thumbs Also See for 5 Series:

Advertisement

®
Evolv
Upper Arm Blood Pressure Monitor
Blood Pressure Monitor
INSTRUCTION MANUAL
INSTRUCTION MANUAL
5 series Upper Arm
Model BP7000
Model BP7200
®
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5 Series and is the answer not in the manual?

Questions and answers

Louis H. Lenert
June 4, 2025

What does the heartbeat symbol at the lower right corner of the display mean when it appears?

RTJ
May 28, 2025

Empty the memory

Subscribe to Our Youtube Channel

Summary of Contents for Omron 5 Series

  • Page 1 ® ® INSTRUCTION MANUAL INSTRUCTION MANUAL ® Evolv Upper Arm Blood Pressure Monitor 5 series Upper Arm Blood Pressure Monitor Model BP7000 Model BP7200...
  • Page 2: Table Of Contents

    Table of Contents Introduction ....................3 Important Safety Information ................5 1. Know Your Monitor ................10 2. Preparation ..................18 3. Using Your Monitor ................25 4. Using Memory Function ...............28 5. Other Settings ..................30 6. Error Messages and Troubleshooting..........32 7. Maintenance ..................36 8. Optional Accessories ................38 9.
  • Page 3: Introduction

    Safety Instructions This instruction manual provides you with important information about the OMRON BP7200 Blood Pressure Monitor. To ensure the safe and proper use of this monitor, READ and UNDERSTAND all of these instructions. If you do not understand these instructions or have any questions, contact 1-800-634-4350 before attempting to use this monitor.
  • Page 4 Symbols Glossary For symbol information, visit: OmronHealthcare.com/symbols-glossary Contraindications • This monitor is contraindicated for use in ambulatory environments. • This monitor is contraindicated for use on aircraft.
  • Page 5: Important Safety Information

    Important Safety Information Read the Important Safety Information in this instruction manual before using this monitor. Follow this instruction manual thoroughly for your safety. Keep for future reference. For specific information about your own blood pressure, CONSULT WITH YOUR PHYSICIAN. Indicates a potentially hazardous situation which, if not Warning avoided, could result in death or serious injury.
  • Page 6 • NEVER diagnose or treat yourself based on your readings. ALWAYS consult with your physician. • To help avoid strangulation, keep the air tube and AC adapter cable away from infants, toddlers and children. • This product contains small parts that may cause a choking hazard if swallowed by infants, toddlers and children.
  • Page 7 • ONLY inflate the arm cuff when it is applied on your upper arm. • Remove the arm cuff if it does not start deflating during a measurement. • DO NOT use this monitor for any purpose other than measuring blood pressure.
  • Page 8 Taking a measurement after an extreme temperature change could lead to an inaccurate reading. OMRON recommends waiting for approximately 2 hours for the monitor to warm up or cool down when the monitor is used in an...
  • Page 9 AC Adapter (optional accessory) Handling and Usage • Fully insert the AC adapter into the outlet. • When unplugging the AC adapter from the outlet, be sure to safely pull from the AC adapter. DO NOT pull from the AC adapter cable. •...
  • Page 10: Know Your Monitor

    1. Know Your Monitor Contents/Product Includes Monitor, 4 “AA” batteries, Wide-Range D-Ring Cuff, instruction manual, quick start guide...
  • Page 11 Monitor and Arm Cuff Front of the monitor Display [Forward/Backward] buttons [Date/Time setting] button [User ID selection] switch [Memory] button [START/STOP] button...
  • Page 12 Left side, back and bottom of the monitor Air jack AC adapter jack (for optional AC adapter) Battery compartment Arm cuff (Upper arm circumference: 9" - 17" (22 - 42 cm)) Air plug Air tube...
  • Page 13 Display and Symbols...
  • Page 14 Memory symbol Appears when viewing readings stored in the memory. Average value symbol Flashes when viewing the average of the latest 2 or 3 readings taken within the most recent 10 minute timeframe. User ID symbol The user ID number appears when selecting the user with [user ID selection] switch.
  • Page 15 Irregular heartbeat symbol Appears when irregular rhythm is detected 2 or more times during a measurement. The symbol with the number appears as below: Irregular heartbeat is detected 2 times: Irregular heartbeat is detected 3 times or more: An irregular heartbeat rhythm is defined as a rhythm that is 25 % less or 25 % more than the average rhythm detected while your monitor is measuring blood pressure.
  • Page 16 Movement error symbol Appears with your reading when your body is moving during a measurement. If it appears, remove the arm cuff and wait for 2 to 3 minutes. Then, reapply the cuff, remain still and take another measurement. Low battery symbol Flashes when batteries are low.
  • Page 17 Classification of BP (Blood Pressure) ACC/AHA 2017 Hypertension guidelines define categories of BP in adults as below. Categories of BP in Adults* BP Category Systolic BP Diastolic BP Normal < 120 mmHg < 80 mmHg Elevated 120 - 129 mmHg and <...
  • Page 18: Preparation

    2. Preparation Installing Batteries 1. Push down on the hook of the battery cover and pull upward. 2. Insert 4 “AA” batteries as indicated in the battery compartment. 3. Close the battery cover. As soon as batteries are correctly installed, the year flashes on the display.
  • Page 19 Setting the Date and Time Note • Set your monitor to the correct date and time before taking a measurement for the first time. • As soon as batteries are correctly installed, the year flashes on the display of your monitor. 1.
  • Page 20 4. Press the button to store the setting. Your monitor automatically turns off 3 seconds after the minutes have been set in this sequence. Note • If you need to reset the date and time, replace batteries or press the button, then set the date and time as shown in above steps.
  • Page 21 • The blood pressure can differ between the right arm and the left arm, and the measured blood pressure readings can be different. OMRON recommends to always use the same arm for measurement. If the readings between both arms differ substantially, check with your physician to determine as to which arm to use for your measurements.
  • Page 22 2. Place your hand through the cuff loop. Pull the cuff until it reaches your upper left arm. Note • The bottom edge of the arm 0.5 inch (1 to 2 cm) cuff should be 0.5 inch (1 to 2 cm) above the inside elbow. The air tube is on the inside of your arm and aligned with your middle finger.
  • Page 23 Sitting Correctly To take a measurement, you need to be relaxed and comfortably seated in a room with a comfortable temperature. Place your arm on the table. • Sit in a comfortable chair with your back and arm supported. • Keep your feet flat and your legs uncrossed.
  • Page 24 Selecting a User ID Your monitor is designed to take measurements and store the readings in the memory for 2 people using the [user ID selection] switch. 1. Select your user ID (1 or 2).
  • Page 25: Using Your Monitor

    3. Using Your Monitor Taking a Measurement Note • To stop the measurement, press the [START/STOP] button once to deflate the arm cuff. Caution • DO NOT use this monitor with other medical electrical (ME) equipment simultaneously. This may result in incorrect operation of the monitor and/ or cause an inaccurate reading.
  • Page 26 3. Press the [START/STOP] button to turn your monitor off. Note • Your monitor automatically turns off after 2 minutes. • Wait 2 - 3 minutes between measurements. The wait time allows the arteries to decompress and return to their pre-measurement state. You may need to increase the wait time depending on your individual physiological characteristics.
  • Page 27  If your systolic pressure is more than 210 mmHg If your systolic pressure is more than 210 mmHg, take a measurement manually. After the arm cuff starts to inflate, press and hold the [START/STOP] button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure.
  • Page 28: Using Memory Function

    4. Using Memory Function Your monitor automatically stores up to 60 readings per user. Note • This monitor can be used by multiple users. Refer to sub-section 2.6 to switch user. Make sure which user ID stores your own readings. Viewing the Readings Stored in Memory 1.
  • Page 29 3. Press the button repeatedly to scroll through the previous readings stored in the memory. : To view the older readings : To view the more recent readings Viewing the Average Reading Your monitor can calculate an average reading based on the latest 2 or 3 readings taken within the most recent 10 minute timeframe.
  • Page 30: Other Settings

    5. Other Settings Deleting All Readings Stored in Memory 1. Select your user ID. 2. Press the button. After a memory number appears, the latest reading will appear. 3. While holding the button down, press and hold the [START/STOP] button for more than 3 seconds.
  • Page 31 Restoring Your Monitor to the Default Settings To delete all the information stored in your monitor, follow the instructions below. Make sure that your monitor is turned off. 1. While holding the button down, press and hold the [START/STOP] button for more than 3 seconds.
  • Page 32: Error Messages And Troubleshooting

    6. Error Messages and Troubleshooting If any of the below problems occur during measurement, check to make sure that no other electrical device is within 12 inches (30 cm). If the problem persists, refer to the table below. Display/Problem Possible Cause Solution Press the [START/ STOP] button again to...
  • Page 33 Display/Problem Possible Cause Solution Remain still and do not talk during a measurement. If “E2” You move or talk during appears repeatedly, a measurement and the inflate the arm cuff arm cuff does not inflate manually until the sufficiently. systolic pressure is 30 to 40 mmHg above your previous readings.
  • Page 34 Display/Problem Possible Cause Solution You move or talk during Remain still and do not a measurement. talk during a Vibrations disrupt a measurement. appears measurement. Apply the arm cuff correctly, then take another measurement. appears Refer to sub-section 2.4. Remain still and sit The pulse rate is not correctly during a detected correctly.
  • Page 35 Display/Problem Possible Cause Solution appears or the Immediately replace all 4 Batteries are depleted. monitor is turned off batteries with new ones. unexpectedly during Refer to sub-section 2.1. a measurement. Batteries are depleted. Nothing appears on Check the battery the display of the Battery polarities are not installation for proper monitor.
  • Page 36: Maintenance

    7. Maintenance Maintenance To protect your monitor from damage, follow the directions below: • Changes or modifications not approved by the manufacturer will void the user warranty. Caution • DO NOT disassemble or attempt to repair this monitor or other components.
  • Page 37 2. Gently fold the air tube into the arm cuff. Note • Do not bend or crease the air tube excessively. Do not store your monitor and other components: • If your monitor and other components are wet. • In locations exposed to extreme temperatures, humidity, direct sunlight, dust or corrosive vapors such as bleach.
  • Page 38: Optional Accessories

    8. Optional Accessories Small D-Ring Cuff Wide-Range D-Ring Cuff Arm circumference Arm circumference 7" - 9" (17 - 22 cm) 9" - 17" (22 - 42 cm) Model: Model: HEM-CS24-B HEM-CS24-BZ HEM-RML31-B HEM-RML31-BZ •Same as the arm cuff provided with the product. Note •...
  • Page 39 Using the AC Adapter (optional accessory) Note • Make sure not to place your monitor in a location where it is difficult to plug and unplug the AC adapter. • We recommend keeping batteries in your monitor at all times, even if you choose to use the AC adapter.
  • Page 40: Specifications

    9. Specifications Model BP7200 HEM-7150-Z Display LCD digital display Cuff pressure range 0 to 299 mmHg Blood pressure SYS: 60 to 260 mmHg measurement range DIA: 40 to 215 mmHg Pulse measurement 40 to 180 beats / min. range Pressure: ±3 mmHg Accuracy Pulse: ±5 % of display reading Inflation...
  • Page 41 Storage / Transport -4 °F to +140 °F (-20 °C to +60 °C) / 10 to 90 % conditions RH (non-condensing) Monitor: Approximately 10.9 oz. (310 g) not Weight including batteries Arm cuff: Approximately 6 oz. (170 g) Monitor: Approximately 4.2" (w) × 3.4" (h) × 6.0" (l) (105 mm ×...
  • Page 42 Pictogram on the Product Types of marks used to indicate the correct positioning of the artery for the upper arm Identifies the type of cuff that is compatible with the blood pressure monitor...
  • Page 43: Fcc Statement

    10. FCC Statement FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 44: Limited Warranty

    The above warranty extends only to the original retail purchaser, and only to products purchased from an Omron authorized seller who is subject to and follows Omron’s quality control standards, unless otherwise prohibited by law.
  • Page 45 OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES OR DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
  • Page 46: Guidance And Manufacturer's Declaration

    12. Guidance and Manufacturer’s Declaration OMRON Battery-operated / AC Adapter-operated Blood Pressure Monitor Information for Accompanying Documents in the Scope of IEC60601-1-2:2014 Important information regarding Electromagnetic Compatibility (EMC) BP7200 conforms to IEC60601-1-2:2014 Electromagnetic Compatibility (EMC) standard. Further documentation in accordance with this EMC standard is available at...
  • Page 47 OMRON HEALTHCARE Co., Ltd 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN Distributed by: OMRON HEALTHCARE, INC. 1925 West Field Court, Lake Forest, IL 60045 U.S.A. OmronHealthcare.com © 2019 OMRON HEALTHCARE, INC. Made in Vietnam 3608857-0I...

This manual is also suitable for:

Bp7200

Table of Contents

Save PDF