3
NXDN™ OPERATION

About other Emergency calls

NOTE:
These functions and operations may or may not be available or different, depending on the presetting.
Ask your dealer for preset information.
Lone Worker Emergency call
When the Lone Worker function is ON, the transceiver
enters the Emergency mode then the countdown for
the Emergency call transmission starts when either/
or:
1. No operation occurs for the set time period.
2. The acceleration sensor detects a lower
acceleration than the set value for the set time
period.
After a set time period has passed, an Emergency call
is automatically transmitted once, or repeatedly.
If the user pushes any key during the first countdown,
the transceiver exits the Emergency mode, and the
Emergency call is cancelled.
You can also cancel the Emergency call by turning
OFF the transceiver.
To turn ON the Lone Worker function, see page 1-4.
Man Down Emergency call
When the transceiver leans past the preset angle for a
set time period, the transceiver enters the Emergency
mode, and then a countdown starts.
After a set time period has passed, an Emergency call
is automatically transmitted once, or repeatedly.
If the transceiver is placed again within the preset
angle, during the first countdown, the transceiver
exits the Emergency mode, and the Emergency call is
cancelled.
You can also cancel the Emergency call by turning
OFF the transceiver.
Motion Detection Emergency call
When the acceleration sensor keeps detecting a
higher acceleration than the preset value for the set
time period, the transceiver enters the Emergency
mode then the countdown starts.
After the set time period has passed, an Emergency
call is automatically transmitted once, or repeatedly.
Countdown beeps sound for the set time period.
If the user holds down [Emergency] for the set time
period during the first countdown, the Emergency call
is canceled.
You can also cancel the Emergency call by turning
OFF the transceiver.