Connect Vent - Whirlpool YWED8800YW0 Installation Instructions Manual

Gas dryer
Table of Contents

Advertisement

Available languages

Available languages

5.
Attach long hose to dryer fill
valve and tighten coupling
(279 mm)
Attach other end of long hose
to fill valve at bottom of dryer
back panel. Screw on coupling
by hand until it is seated on fill
valve connector. Using pliers,
tighten the couplings an additional
two-thirds turn.
NOTE: Do not overtighten. Damage
to the coupling can result.
6.
Turn on cold water faucet
Check that the water faucets are turned on.
7.
Check for leaks
Check for leaks around "Y" connector, faucets, and hoses.
3
/
"
3
4
(95 mm)
11"

CONNECT VENT

1.
Connect vent to exhaust outlet
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
2.
Move dryer to final location
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove cardboard from under dryer.
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents