Configuring the Devices
Configuration procedure of devices
1
See
p. 45
2
See
p. 47
3
See
p. 49
Configuring the PFX2512
You can change the following settings using the S1 switch on the rear panel. If you change a
setting, turn the PFX2512 off and then back on.
• Channel numbers
• Vibration sensor
Factory default switch position
Example of channel number 1
PFX2512
Set the channel numbers and vibration sensor using the S1 switch of the
PFX2512.
Configure the DC power supply.
Set protection functions, external analog control, and panel lock.
Configure the electronic load.
Configure the protection function, slew rate, external analog control, panel lockand if
necessary, parallel operation.
Signal name
TERMN OFF
NC
1
2
4
8
RESV
SH DET
1
Logic
1
Not used
Not used
Set channel numbers
(1 to 7).
0 is not allowed.
Not used
0: Vibration sensor off
1: Vibration sensor on
TP-BUS connector is not used on the PFX2512.
Notes
Factory
default
Always set to
0
ze
Always set to
0
zero
−
1
−
0
−
0
−
0
Always set to
0
zero
−
0
2