Crown GL-40E Installation & Operation Manual page 13

Gas fired steam jacketed stationary
Hide thumbs Also See for GL-40E:
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL, GAS KETTLES
4.0 OPERATION (Continued)
GAS CONTROL INSTRUCTIONS: (Continued)
7.
When the pilot is ignited the spark igniter will automatically stop and within 15 seconds
main burner gas will come on. If ignition does not occur, after a total of ninety
seconds, the unit will lockout, shutting off all gas although the spark igniter will
continue to spark. New installations (where there may be a considerable amount of air
in the gas line) may require the unit to be turned off and immediately back on
numerous times after each lockout period until the air is purged from the gas line.
B. SHUTDOWN
1. STANDBY
1. Place power on switch and thermostat to "OFF" position.
2. COMPLETE
1. Place power on switch and thermostat to "OFF" position.
2. Turn dial on combination control from "ON" position to "OFF" position.
3. Turn any main gas service valves supplying gas to "OFF" position.
C. RELIGHTING
1. Turn power switch to "ON" position.
It should be noted that the pilot and electronic ignition do not cycle with the thermostat. A
standing pilot is automatically established and monitored each time the power switch is turned
ON. If the pilot is ever extinguished by a momentary external interruption, the spark igniter will
automatically relight it without disturbing the cooking cycle, unless lockout occurs.
10125R4
Models GL-20E, GL-40E, GL-60E, GL-80E, GL-100E
13
2017-08-29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gl-30eGl-20eGl-60eGl-80eGl-100e

Table of Contents