Igloo C3URP Series Instruction Manual
Igloo C3URP Series Instruction Manual

Igloo C3URP Series Instruction Manual

Pastry display cases

Advertisement

Quick Links

Instruction Manual
Pastry Display Cases
Models: C3URP series
C3URLP
C3URP
C3URHP
124 Norfinch Dr. Toronto, ON. M3N 1X1
Tel : 416-663-3051 Fax : 416-663-5793
REFRIGERATION LTD.
Toll Free : 1-888-408-8819

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C3URP Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Igloo C3URP Series

  • Page 1 Instruction Manual Pastry Display Cases Models: C3URP series C3URLP C3URP C3URHP 124 Norfinch Dr. Toronto, ON. M3N 1X1 Tel : 416-663-3051 Fax : 416-663-5793 REFRIGERATION LTD. Toll Free : 1-888-408-8819...
  • Page 2: Table Of Contents

    REFRIGERATION LTD Contents Contents ................................2 1 UNLOADING ..............................3 2 PROPERTIES OF THE UNIT..........................3 2.1. Purpose ..............................3 2.2. Description of the unit ..........................3 2.3. Technical data ............................4 3. PREPARING THE DEVICE FOR START UP ......................5 3.1.
  • Page 3: Unloading

    REFRIGERATION LTD 1 UNLOADING The unit should be transported in vertical position and properly secured and packed. 2 PROPERTIES OF THE UNIT 2.1. Purpose “C3URP” series display cases are universal cooling devices that are aimed to display and are used for short-term storage for confectionery goods (such as cakes, cookies, desserts…...
  • Page 4: Technical Data

    5 – Top internal LED lamp 12 – Condenser cover (DO NOT BLOCK air louver!!!) 6 – Front frame LED lamp 13 – Leveling legs 7 – Straight front glass Other C3URP series C3URLP:1 Shelf C3URHP:3 Shelves 2.3. Technical data Table 1 Technical data...
  • Page 5: Preparing The Device For Start Up

    Never plug in more than one unit per electric circuit.  If in doubt, call an electrician. IGLOO will not warranty any equipment that is connected to an extension cord or adapter plug. The equipment may be turned on after confirmation of the fire protection efficiency with results of measures performed according to binding regulations! ■...
  • Page 6: Connection And Start-Up

    REFRIGERATION LTD  Humidity may cause rust, condensation around glass or stainless steel and decrease the efficiency of the unit. 3.3. Connection and start-up  Unpack the unit.  Place the unit on an even and hard base. Then level the unit with the leveling legs. ...
  • Page 7: Unit Start Up

    REFRIGERATION LTD 4. UNIT START UP Temperature of the cooled space and aggregate operating cycle may fluctuate. This depends on numerous factors, such as amount and temperature of products placed in the device and temperature of the surroundings. The equipment should be placed in a dry and well-ventilated place, ensuring proper air exchange (distance between the wall and the equipment–...
  • Page 8: Figure 4 "Carel" Thermostat Control Panel

    REFRIGERATION LTD It is forbidden to interfere with systemic parameters of the thermostat, as this can lead to serious consequences, including the damage of the cooling unit! Figure 4 “Carel” thermostat control panel QuickFinder for CAREL WHAT DO DIODES ON CONTROL PANEL SIGNIFY Diode 1 - Compressor: This symbol is visible when the compressor is working.
  • Page 9: Table 2 Table Of Alarms And Signals

    REFRIGERATION LTD Defrosting shall be released in an automatic mode. It is possible to force defrosting at any moment by pressing and holding the defrost switch for minimum 5 seconds. Table 2 Table of alarms and signals buzzer and alarm alarm code alarm description reset...
  • Page 10 REFRIGERATION LTD probe 1 offset °C -50.0 50.0 probe 2 offset °C -50.0 50.0 probe 3 offset °C -50.0 50.0 control differential °C 19.0 minimum set point value °C -50.0 maximum set point value 15.0 °C select direct/reverse operation night-time set point delta °C compressor and fan start delay on power-up minimum time between consecutive compressor starts...
  • Page 11: Maintenance

    REFRIGERATION LTD 5. MAINTENANCE  Before you start Maintenance on the unit, Power it OFF.  Do not use steel wool, abrasive cleaners, bleach or cleaners containing chlorine or sodium to clean the unit.  Do not use pressure washer or water-jet to clean the unit. ...
  • Page 12: Service

    REFRIGERATION LTD It is recommended to make a break in the operation once a month in order to clean the interior, naturally defrost the evaporator and clean the condenser Figure 6 Cleaning the condenser It is essential to keep the condenser of the device clean. Dirt may hinder the heat exchange, causing mainly an increase in electric energy consumption and may cause damage of the compressor.
  • Page 13 REFRIGERATION LTD • The main switch is turned on. • Thermostat is turned on. The equipment is operating, but the light is off... – Make sure that: • Light switch is turned on. • Lamp or starting switch of the equipment are not burnt. Water leakage from under the device •...
  • Page 14: Service

    Telephone number: 416-663-3051 or (toll free) 1-888-408-8819 E-mail: service@igloo400.com If after checking points described in chapter 6.1 “Faults identification and repair” and the equipment still does not work properly, Please contact Technical Service @ IGLOO Refrigeration. www.igloorefrigeration.com Pastry Display Cases...