TRIMLINE 13NP47 SERIES Keep This Manual With Air Conditioner AIR CONDITIONER OPERATOR'S MANUAL CAUTION KOOLTRONIC, INC. 30 Pennington-Hopewell Road BEFORE INSTALLING AND Pennington, NJ 08534 USING THIS AIR CONDITIONER, 609 • 466-3400 IT IS IMPORTANT THAT THIS MANUAL BE READ AND FAX: 609 •...
Warranty I. Introduction Kooltronic Air Conditioners are designed to provide a cool, dehumidified environment for your electronic components. There are models to fit virtually all sizes and shapes of electronic enclosures, in capacities ranging from 1,000 to 30,000 BTU/H. Our "closed-loop" design also ensures that your components will not be exposed to hot, dirty operating conditions.
Manual. See section VI PRE-INSTALLATION TESTING. 2) Before operating the Kooltronic Air Conditioner be certain that it is placed in its correct mounting position. All Air Conditioners containing an MM, NM, P, or V as part of the model number are designed to operate in a vertical position only.
IV. Product Identification and Nameplate Each Kooltronic Air Conditioner includes an identification nameplate. This nameplate provides: Model Number Serial Number Electrical power characteristics Maximum and minimum ambient operating temperatures Cooling capacity Type and amount of refrigerant required for recharging Design Pressure...
V. Principles of Operation Kooltronic Air Conditioners are CONDENSER OUTLET required when the equipment (Heated Ambient Air Out) operating temperature must be HEATED AIR CONDENSER FROM ENCLOSURE kept near or lower than the ambient HEAT EXCHANGER room temperature, and/or the...
9. If any cover plug was removed to adjust the unit, be sure to replace it in order to maintain the integrity of the closed-loop airflow system. NOTE: Before shipment all Kooltronic Air Conditioners are subjected to a performance test.
4" high. Make sure the cutouts don't interfere with components inside your cabinet. 4. Mount the M/TAB to the outside of the cabinet using all the mounting hardware supplied by Kooltronic -20 screws/nuts/washers). NOTE: Make sure the screws are inserted with heads on M/TAB side.
Wiring Schematic EVAP. BLOWER MOTOR CAP. SUPPRESSOR CRANKCASE HEATER THERMAL CUTOUT OPTIONAL HEATER T-STAT SET 40° 230 V 115 V RELAY COMPRESSOR CAP. COND. OPTIONAL BLOWER MOTOR CAP. PRESSURE START ASSIST SWITCH 115 V ONLY TERMINAL BLOCK COOLING EFFECT DETECTOR RED TO YELLOW CLOSES ON TEMPERATURE YELLOW...
3) The filters may be sprayed with Kooltronic A-16 Filter Recoating Adhesive to trap fine airborne contaminants, or they may simply be dried and reinstalled as strainer type filters. Recoating is recommended for best results.
Page 12
B. Blowers The design life of the blowers used in all Kooltronic Air Conditioners is substantially in excess of 20,000 hours. All Kooltronic condenser and evaporator blowers are equipped with automatic-reset thermal overload protectors. CAUTION Before opening the air conditioner, disconnect all power.
IX. Trouble-Shooting Each Kooltronic Air Conditioner is engineered for performance and built for reliability. They are designed to require no routine maintenance other than the cleaning of ambient air filters. If your air conditioner should require service, we have compiled a trouble-shooting chart to assist your service personnel.
THIS WARRANTY CONSTITUTES THE ENTIRE WARRANTY WITH RESPECT TO THE PRODUCT AND IS IN LIEU OF ALL OTHERS, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY AND WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT IS KOOLTRONIC RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER.