M-system R7C-RS4 Instruction Manual

Rtd input module, 4 points

Advertisement

Quick Links

INSTRUCTION MANUAL
RTD INPUT MODULE, 4 points
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
RTD input module ...............................................................(1)
Terminating resistor (110 Ω, 0.5 W) ...................................(1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
• Install lightning surge protectors for those wires connect-
ed to remote locations. Choose a surge protector with its
maximum surge voltage 40V or less between lines. Rec-
ommended M-System model: MDP-D24.
■ POWER INPUT RATING & OPERATIONAL RANG
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 90mA
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
(CC-Link V.1.10)
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
MODEL
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
R7C-RS4
EM-7801-C Rev.6 P. 1 / 10

Advertisement

Table of Contents
loading

Summary of Contents for M-system R7C-RS4

  • Page 1 • Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Thank you for choosing M-System. Before use, please check • Do not bind these cables together with those in which contents of the package you received as outlined below.
  • Page 2: Component Identification

    • Extension (SW1-1, 1-2) SW1-1 SW1-2 EXTENSION No extension (*) Discrete input, 8 or 16 points Discrete output, 8 or 16 points EM-7801-C Rev.6 P. 2 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 3: Indicator Led

    Depends on sensor type 0.00 (degC) ■ EXTENSION MODULE SETTING PARAMETER AVAILABLE RANGE DEFAULT SETTING Output Hold/Clear Output Hold Output Hold Output Clear EM-7801-C Rev.6 P. 3 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 4: Terminal Connections

    In order to improve EMC performance, bond the FG terminal to ground. Caution: FG terminal is NOT a protective conductor terminal. Input Connection Example INAn INBn INbn EM-7801-C Rev.6 P. 4 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 5: Communication Cable Connections

    Reserved • With Extension Module R7C-EC16x Interval-timed Response (X) Refresh Data (Y) RX(n+0)F to RX(n+0)0 (Status) RY(n+0)F to RY(n+0)0 (R7C-EC16x) Reserved Unused EM-7801-C Rev.6 P. 5 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 6: Wiring Instructions

    Applicable wire size: 0.25 to 1.65 mm (AWG 22 to 16) Recommended manufacturer: Japan Solderless Terminal MFG. Co., Ltd, Nichifu Co., Ltd 3.3 (.13) max mm (inch) EM-7801-C Rev.6 P. 6 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 7 CE mark which shows that the product conforms with the requirements of EU Directive. Each EU Directive describes the scope of apparatuses to which that EU Directive is applied. M-System’s R7C must conform with EMC Directive. Each Directive states only basic requirements. In order to mark the CE on an assembled machinery equipment, its manufac- turer needs to check the overall conformity with Directives applicable to it.
  • Page 8 Shielding is strengthened the opening. by using an electro- Ground the control panel magnetically shielded at low impedance using control panel. (e.g.) braided wires. EM-7801-C Rev.6 P. 8 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 9 • Ferrite core that is attached to signal cables. • Noise limiting circuit (surge quenching circuit, transient absorber circuit, etc.) that is enclosed in signal cables. EM-7801-C Rev.6 P. 9 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 10 To external apparatus Grounding in pig tail form Motor is not effective. Drive Cable Maintain distance between cables and noise sources. EM-7801-C Rev.6 P. 10 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...

Table of Contents