Using the mains rectifier

e
Warning!
Do not reverse the polarity. If the poles are reversed device may
overheat and be damaged.
a
Caution!
Replace defective fuses with new ones of the same rating (12 A
slow-blow).
e
Warning!
Ensure that the battery's positive supply line is secured with a fuse
(fig. 2 1, page 3) of the following value:
– at 12 Vg: 15 A
– at 24 Vg: 7.5 A
The fuse must be installed as close to the battery as possible.
To avoid drops in voltage and therefore performance, keep the cable route
as short as possible and only disconnect it when necessary.
The cables between mains rectifier and compressor must not exceed 1.5 m
and must have a cross section of at least 2.5 mm²!
➤ Fit wire sleeves to the ends of wires which you wish to connect to the
mains rectifier.
➤ Connect the battery using the B+ and B– terminals on the front plate
(fig. 3, page 3).
➤ Connect the BDF-50 compressor
– using the C+ and C– terminals (fig. 4 1, page 3) or
– using the socket on the front plate (fig. 4 2, page 3).