Safety Cable Use

The supplied safety cable MUST always be used when rigging luminaires on bars, truss, etc. (as shown in
The supplied safety cable is recommended for all hanging installation and may be required by national and local
codes. Loop or attach safety cable to luminaire safety cable anchor point as shown and attach to structure. You should
always consult and follow all local and national codes and regulations for mounting and installation of luminaire.

5. Pan and Tilt Adjustments

Pan Adjustment

The pan adjustment of a PLPROFILE1 MKII LED Luminaire is achieved by loosening the yoke bolt of the securing
clamp attached to the luminaire's yoke assembly. Loosen the bolt, set the luminaire to the desired position and re-
tighten.

Tilt Adjustment

PLPROFILE1 MKII LED Luminaires offer variable tilt settings. The unit can be set at a specific angle (in relation to
its mounting position) or at an angle between 0 to 90 degrees. When the yoke is in the position shown in
have full range access to shutters the gate etc. If you flip the yoke over some access is reduced but the over all volume
the luminaire takes up is reduced. This is particularly useful in tightly hung lighting positions or in theatres with low
grids.
Safety Cable
(supplied with
luminaire)
Safety Cable
Anchor Point.
T-Handle Tilt Lock
Sliding Yoke Assembly
To adjust and set tilt angle of the luminaire:
Step 1. Mount luminaire in desired location (see
Step 2. Loosen, but do not remove, T-Handle Tilt Lock at base of yoke assembly as shown in
Step 3. Position luminaire to desired tilt position.
Step 4. Hand-tighten T-Handle Tilt Lock to set position.
1 0
INSTALLATION AND SET UP
SAFETY CABLE: FOR LUMINAIRE, the supplied safety cable is
recommended for all hanging installation and may be required by
national and local codes. Loop/attach safety cable to safety cable anchor
point (as shown) and attach to structure.
Figure 6: Luminaire Tilt Adjustment
"Mounting" on page 9
PLPROFILE1 MKII LED Luminaires
Cooling Vents (see note below)
Yoke Assembly
NOTE: To allow for proper cooling, make
sure luminaire head is orientated as shown
(with cooling vents pointed upwards).