are and Cleaning
CONTINUED FROM PAGE 21
Container
1. To clean: Fill pitcher 1/4 full with warm (110˚F/43˚C) water and add a couple
drops of dish soap.* Return container to motor base and firmly position the two-
part lid. Run machine for 30 seconds. Empty container. Repeat this step.
*NOTE: For maximum container life, do not wash in dishwasher.
2. Fill pitcher 1/4 full with warm (110˚F/43˚C) water (do not add soap). Return
container to motor base and firmly position the two-part lid. Run machine for
30 seconds. Empty container.
3. If any solid residue remains, remove the blade agitator assembly (see page 17)
and wash all container parts in warm soapy water. Rinse and drain. Reassemble
before next step.
DO NOT soak the blade agitator assembly.
4. To sanitize: If all solid residue is gone after step 2 or after completion of step 3,
fill container 1/4 full with a sanitizing solution mix.** Return container to motor
base and firmly position the two-part lid. Run machine on HIGH for 30 seconds.
Empty container.
5. Return container to motor base and run machine empty for an additional
5 seconds. Do not rinse after sanitizing.
**Recommended sanitizing solution: 1-1/2 teaspoons Clorox
bleach, in 2 quarts (2.0 liter) water.
Important: Check your blades daily for loose, nicked or missing
parts. If you find something is loose, nicked or missing, replace
the blade assembly before use. Do not tighten hex-headed screw
(on top of blade assembly). If loose, replace blade assembly.