ELECTRICAL INSTALLATION — IPI
Label all wires before disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
WARNING: Electrical connections should
only be performed by a qualifi ed, licensed
electrician. Main power must be off
when connecting to main electrical power
supply or performing service. All wiring shall
be in compliance with all local, city and state
codes. The appliance, when installed, must be
electrically grounded in accordance with local
codes or in the absence of local codes, with
the National Electrical Code ANSI/NFPA 70
(latest edition) and Canadian Electrical Code,
CSA C22.1.

ELECTRICAL WIRING

General
1. This fi replace is equipped with an IPI control valve which
operates on 6 volts. The 6 volt DC adapter plugs into
the fi replace junction box A/C power supply.
2. The IPI system can also be operated without A/C power.
The system can run on four (4) "AA" batteries using the
optional battery backup for approximately six (6) months
under normal use.
Optional Accessories
This fi replace may be used with a wall switch, wall mounted
thermostat or IPI hand held remote control.
20308011
WARNING: Do NOT connect to a
110V circuit.

JUNCTION BOX WIRING

1. This should be done before framing the fi replace. Wire
the receptacle into an electrical circuit. Wire with mini-
mum 60° C wire in accordance with prevailing codes.
2. Remove the external junction box cover by removing
the screw from the side of the outside fi rebox wall.
Junction box was installed at the factory.
3. The junction box cover has a factory installed "romex"
style strain relief connector. After connecting the wires,
route the wire leads through this connector. Refer to
the wiring diagram in Figure 18.
Junction Box
Figure 18 –
Junction Box Wiring Diagram
VFC Vent Free Fireplace System
120V AC
Factory Supplied
Not Supplied
60Hz