5.1.6
Main Components
FOR WH-MXC09J3E8
15
14
Component name
PCB
1
3 phase RCCB (Main Power)
2-1
Single or 3 phase RCCB (Backup Heater)
2-2
Heat Exchanger
3
4
Water Pressure gauge
Water pump
5
Cabinet top plate
6
Expansion vessel (Not Visible)
7
Flow sensor
8
It is advisable to avoid more than 2 blockage directions. For better ventilation
& multiple-outdoor installation, please consult authorized dealer/specialist.
6
1
2-1
2-2
4
12
8
A
9
3
7
11
5
6
FOR WH-MXC12J9E8 & WH-MXC16J9E8
Heater assembly
9
Overload protector (4 pieces)
10
Pressure relief valve
11
Air purge valve
12
13
Water Filter Set
Plug (2 pieces)
14
Bushing (6 pieces)
15
Cabinet front plate
16
Cover
17
33
1
2-1
2-2
4
12
8
A
b
9
3
a
7
11
13
5
16
Connector name
Water inlet
a
b
Water outlet
10
DETAIL A
17