Panasonic WH-MXC16J9E8 Service Manual page 30

Air-to-water heatpump, mono bloc unit
Hide thumbs Also See for WH-MXC16J9E8:
Table of Contents

Advertisement

Menu
6.3
*
1,
*
2
Auto
Automatic switch from Heat to
Cool or Cool to Heat.
6.4
Tank
Setting functions for the tank.
• Available only if connected to
the tank.
*
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
1
*
Only displayed when COOL mode is unlocked (This means when COOL mode is available).
2
Default Setting
Setting Options / Display
Water temp. for cooling ON Direct
Set temperature for
10°C
Cooling ON
• If 2 zone system is selected, temperature set point must input for Zone 2.
• "Zone 1" and "Zone 2" will not appear on the display if only 1 zone system.
T for cooling ON
Set T for cooling ON
* This setting will not
5°C
available to set when
pump flowrate set to
Max. duty.
Outdoor temperatures for switching from Heat
to Cool or Cool to Heat.
Outdoor temp. for (Heat to Cool) /
Outdoor temp. for (Cool to Heat)
Outdoor temp. for (Heat to Cool)
Set outdoor
temperature for
15°C
switching
from Heat to Cool.
Outdoor temp. for (Cool to Heat)
Set outdoor
temperature for
10°C
switching
from Cool to Heat.
Floor operation time (max) /
Tank heat up time (max) /
Tank re-heat temp. /
Sterilization
• The display will show 3 functions at a time.
Floor operation time (max)
Maximum time for
8:00
floor operation
(in hours and minutes)
30