Download Print this page

LG LSXS26386D Service Manual page 58

Advertisement

Troubleshooting
5. Reference
1) TEST MODE and Removing TPA
1.How to make TEST MODE
If you push the test button on the Main PCB, the refrigerator will be enter the TEST MODE
* 2 times :Forced defrost mode
* 1 time :Comp / Damper / All FAN on
(All things displayed)
(22 22 displayed)
Main PWB
2. How to remove Terminal Position Assurance (TPA)
<
A
C
T
P
A
>
<
D
C
T
P
A
>
After measure the values, you should put in the TPA again.
3. Wire Color
BL : Blue
WH :White
BO : Bright Orange
BK : Black
BN : Brown
PR : Purple
RD : Red
GN : Green
SB : Sky Blue
GY : Gray
PK : Pink

Advertisement

loading