7. The divisions of clamp setting [OFB] = 4
Setting of [FN],[CF] is invalidated when above setting.
Clamp(O1,O2),(O3,O4) is link movement when above setting
The presser block to be used is [F2BN] and can be set.
The holding block that makes the
The clamp step
(forward direction)
general input signal FSP
The clamp step
(backward direction)
general input signal FSM
Start input signal
SRT
Clamp output 1
OF1
Clamp output 2
OF2
Clamp output 3
OF3
Clamp output 4
OF4
Movement of
sewing machine
8. Oil lubrication output setting [OILV] = ON.
Oil lubricate timing set by [OL1C/2C] and [OL1T/2T].
[OL1C/2C] is not clear by after next sewing, this number is accumlate.
DSW
FEED
SEW
OIL1
OIL2
clamp step
[WHY] = OF,[OFB] = 4,[F2BN] = 2,[F2SN] = 2
When not using the clamp step input.
ON
ON
1A ON
1B
2A
ON
2B
OL1C/2C
OL1C/2C
OL1T/2T
OL1T/2T
(When using the clamp step input.)
motion can be set with [F2SN].
ON
ON
1A ON
2A
ON
3A
ON
4A
ON
OL1C/2C
[7] ‐ 5
ON
ON
OL1C/2C
OL1T/2T
OL1T/2T