5. Connecting a gate motorisation system
Use a cable cross-section of 22 mm
IMPORTANT: for the information
feedback to be properly managed,
the position contact (ref. D8921 on
the price list) must be wired before
power-up and be in closed position
when the radio link is established
between the handset and the
controller. If no contact is connected,
the handset display will show the
gate is closed whatever its status.
The position contact feeds back the gate
status to the screen:
-
gate closed (contact closed),
-
gate open (contact open).
2
(telephone type wire) to connect the system.
9 10 11 12 13 14
C
NC NO
NC
Gate motorisation control,
48 V DC/1 A dry contact relay output.
The motorisation system requires
an external power supply.
If a push-button allowing manual
control of the automatic system has
already been installed, connect
terminal blocks 12 and 14 in parallel
on this manual control input.
3.5
197