Connect the cable to the outdoor unit
1. Remove the electrical control board
cover from the outdoor unit by
loosening the screw.
2. Connect the connective cables to
the terminals as identified with their
respective matched numbers on
the terminal block of indoor and
outdoor units. The connective cable
to power supply shall be approved
polychloroprene sheathed flexible
cord.
3. Secure the cable onto the control
board with the cord clamp.
4. To prevent the ingress of water,
form a loop of the connective cable
as illustrated in the installation
diagram of indoor and outdoor
units.
5. Insulate unused cords (conductors)
with PVC-tape. Process them so they
could not touch any electrical or
metal parts.
Single split terminal block
Indoor unit A
L1 L2
L1 L2
26000 Btu/h Multi split terminal block
Indoor unit B
Indoor unit C
33400 Btu/h Multi split terminal block
Indoor unit A
Indoor unit B
Indoor unit D
Electrical work
Cover
Screw
Indoor unit C
Indoor unit E
18