Electrical Work - Frigidaire FFHP093WS2 Installation Manual

Table of Contents

Advertisement

Electrical work

Electric safety regulations for the initial installation
1. If there is serious safety problem
about the power supply, the
technicians should refuse to install
the air conditioner and explain
to the client until the problem is
solved.
2. Power voltage should meet the
requirements in table 2.1.
3. Over current protection and
circuit disconnect should meet
the requirements in table 2.1 and
the applicable local and national
electrical codes.
System
Operating
Capacity
Voltage
Voltage
(BTU/h)
Volts-Ph.-
(Min/Max)
Freq
9000
208/230-1-60 187/253
12000
208/230-1-60 187/253
18000
208/230-1-60 187/253
22000
208/230-1-60 187/253
28000
208/230-1-60 187/253
33600
208/230-1-60 187/253
26000
208/230-1-60 187/253
34400
208/230-1-60 187/253
Connecting (Power and Control Cable)
cable from the outdoor unit to indoor unit consists of four wires and provides
the power for the indoor unit as well as the communication signal and ground
between the outdoor and indoor unit. Two wires are high voltage AC power,
one is low voltage DC signal and one is a ground wire.
(Canadian Electrical Code) for special requirements.
Electrical Data Table 2.1
Compressor
Outdoor Fan
Output
RLA
LRA
FLA
Watts
30
6.60
/
0.14
6.60
/
0.14
30
60
12.08
/
0.49
14.67
/
0.65
90
13.50
40
0.45
120
17.50
67
0.73
170
15.82
/
0.59
90
15.60
/
0.82
170
4. Ensure the air conditioner is
grounded well.
5. All wiring must comply with local
and national electrical codes and
be installed by qualified and skilled
electricians.
6. An individual branch circuit used
only for this air conditioner must be
available. See table 2.1.
Indoor Fan
Output
Volts
FLA
Watts
208/230V-AC
0.36
20
208/230V-AC
0.36
20
208/230V-AC
0.24
20
208/230V-AC
0.38
92
208/230V-AC
0.40
40
208/230V-AC
0.47
60
/
/
/
/
/
/
Electrical work
Max. Fuse/Circuit
MIN. Circuit
Breaker
Ampacity
(MCA)
Amps(MOP)
9
15
9
15
16
25
30
20
30
20
40
24
21
35
21
35
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ffhp123cs2Ffhp123ws2Ffhp183ws2Ffhp183cs2