Summary of Contents for GORMAN-RUPP PUMPS SUPER T T4A60S-4LE2T FT4 Series
Page 1
OM-07080-01 November 30, 2016 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WITH PARTS LIST SUPER T SERIES PUMP MODEL T4A60S-4LE2T FT4 GORMAN‐RUPP PUMPS www.grpumps.com 2016 Gorman‐Rupp Pumps Printed in U.S.A.
Page 2
Register your new Gorman‐Rupp pump online at www.grpumps.com Valid serial number and e‐mail address required. The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. RECORD YOUR PUMP MODEL AND SERIAL NUMBER Please record your pump model and serial number in the spaces provided below.
SUPER T SERIES OM-07080 INTRODUCTION Thank You for purchasing a Gorman‐Rupp pump. HAZARD AND INSTRUCTION Read this manual carefully to learn how to safely DEFINITIONS install and operate your pump. Failure to do so could result in personal injury or damage to the The following are used to alert maintenance per...
SUPER T SERIES OM-07080 SAFETY ‐ SECTION A This information applies to Super T the positive battery cable before per Seriesr engine driven pumps. Refer to forming any maintenance. Failure to do the manual accompanying the engine so may result in serious personal injury. before attempting to begin operation.
Page 7
OM-07080 SUPER T SERIES charge valve, pump components will gines presents an extreme explosion deteriorate, and the liquid could come and fire hazard. Make certain that all to a boil, build pressure, and cause the fuel lines are securely connected and pump casing to rupture or explode.
SUPER T SERIES OM-07080 INSTALLATION - SECTION B Review all SAFETY information in Section A. specific application. Since the pressure supplied to the pump is critical to performance and safety, Since pump installations are seldom identical, this be sure to limit the incoming pressure to 50% of the section offers only general recommendations and maximum permissible operating pressure as practices required to inspect, position, and ar...
OM-07080 SUPER T SERIES Table 1. Battery Specifications PREINSTALLATION INSPECTION Cold Reserve Approx. Amp/ Crank Capacity Overall Voltage The pump assembly was inspected and tested be Amps Dims. @ 80 (Minutes) (Inches) Rating fore shipment from the factory. Before installation, 10.25L inspect the pump for damage which may have oc...
SUPER T SERIES OM-07080 Drain the pump and remove all customer‐installed ing piping couplings in suction lines is not recom equipment such as suction and discharge hoses mended. or piping before attempting to lift existing, installed units. Line Configuration Keep suction and discharge lines as straight as Mounting possible to minimize friction losses.
OM-07080 SUPER T SERIES stalled with the flat part of the reducers uppermost sump at a distance equal to 1 1/2 times the diame to avoid creating air pockets. Valves are not nor ter of the suction line. mally used in suction lines, but if a valve is used, If there is a liquid flow from an open pipe into the install it with the stem horizontal to avoid air pock...
SUPER T SERIES OM-07080 Figure 2. Recommended Minimum Suction Line Submergence vs. Velocity FLOAT SWITCHES above the point where it bends along the bot tom. Direct the suction line toward the flow, and the float(s) away from the flow. If a stand Installation pipe is available, attach the float switch cable to the standpipe in the sump at the approxi...
OM-07080 SUPER T SERIES ENGINE (0.9) CONTROL (.76) (Emptying) (0.6) (Filling) (.46) OPERATING (0.3) RANGE CABLE (See Table Below) TETHER (.15) POINT (Emptying) (0.3) (0.6) (0.9) (1.2) APPROXIMATE FREE CORD LENGTH IN FT. (M) 1.25” Pipe (Filling) (Not Furnished) Figure 3. Float Switch Data OPTIONAL SUBMERSIBLE above the point where it bends along the bot...
SUPER T SERIES OM-07080 SUCTION LINE DISCHARGE LINE SIGNAL CABLE (ATTACH TO SUCTION LINE) SUCTION SUBMERSIBLE STRAINER TRANSDUCER (DOWNSTREAM FROM SUCTION) FLOW Figure 4. Typical Submersible Transducer Installation DISCHARGE LINES Siphoning If the application involves a high discharge Do not terminate the discharge line at a level lower head, gradually close the discharge than that of the liquid being pumped unless a si...
OM-07080 SUPER T SERIES NOTE matic air release valve in a below‐ground lift station), if a manual shut‐off valve is in The bypass line should be sized so that it does not stalled anywhere in a bypass line, it must affect pump discharge capacity;...
SUPER T SERIES OM-07080 Consult the manual accompanying the Air Release pendently mounted in a horizontal position be Valve for additional information on valve installation tween the pump discharge port and the inlet side of and performance. the discharge check valve (see Figure 5). The inlet opening in the Air Release Valve is equipped with Air Release Valve Installation standard 1‐inch NPT pipe threads.
OM-07080 SUPER T SERIES OPERATION - SECTION C OPERATION Review all SAFETY information in Section A. Make sure the pump is level. Lower jack Follow the instructions on all tags, labels and stands and chock the wheels, if so decals attached to the pump. equipped.
OM-07080 SUPER T SERIES Add liquid to the pump casing when: continuous operating speed for this pump. 1. The pump is being put into service for the first time. A Gorman‐Rupp automatic air release valve may 2. The pump has not been used for a consider be installed in a bypass line, or the bypass line may able length of time.
OM-07080 SUPER T SERIES the source of the leak, check the point of installa OPERATION IN EXTREME HEAT tion of the vacuum gauge. The safety shutdown system will automatically stop the unit if engine operating temperature ex Liquid Temperature And Overheating ceeds design limits.
OM-07080 SUPER T SERIES STOPPING shutdown before putting the unit back into service. Consult the factory for ad ditional information. Manual Stopping PERIODIC CHECKS In the manual mode, reduce the throttle speed slowly, and allow the engine to idle briefly before Seal Cavity and Bearing Lubrication shutting down the engine.
Page 21
OM-07080 SUPER T SERIES Consult the manual accompanying the engine, for approximately one minute; this will remove any and change the oil filter periodically as indicated. If remaining liquid that could freeze the pump rotat operated under extremely dusty conditions, ing parts.
Page 22
SUPER T SERIES OM-07080 TROUBLESHOOTING - SECTION D Review all SAFETY information in Section A. 5. Close the suction and discharge valves. 6. Vent the pump slowly and cau tiously. 7. Drain the pump. Before attempting to open or service the pump: 1.
Page 23
OM-07080 SUPER T SERIES TROUBLE POSSIBLE CAUSE PROBABLE REMEDY PUMP STOPS OR FAILS Impeller or other wearing parts Replace worn or damaged parts. TO DELIVER RATED worn or damaged. Check that impeller is properly cen tered and rotates freely. FLOW OR PRESSURE (cont.) Impeller clogged.
Page 24
SUPER T SERIES OM-07080 equipped) between regularly scheduled inspec PREVENTIVE MAINTENANCE tions can indicate problems that can be corrected Since pump applications are seldom identical, and before system damage or catastrophic failure oc pump wear is directly affected by such things as curs.
Page 25
SUPER T SERIES OM-07080 PUMP MAINTENANCE AND REPAIR ‐ SECTION E MAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WILL MAINTAIN PEAK OPERATING PERFORMANCE. STANDARD PERFORMANCE FOR PUMP MODEL T4A60S-4LE2T FT4 Based on 70 F (21 C) clear water at sea level Contact the Gorman‐Rupp Company to verify per...
Page 26
OM-07080 SUPER T SERIES ILLUSTRATION PARTS PAGE 29.13 Figure 1. Pump Model T4A60S-4LE2T FT4 PAGE E - 2 MAINTENANCE & REPAIR...
Page 27
SUPER T SERIES OM-07080 PARTS LIST Pump Model T4A60S-4LE2T FT4 (From S/N 1629692 Up) If your pump serial number is followed by an “N”, your pump is NOT a standard production model. Contact the Gorman‐Rupp Company to verify part numbers. ITEM PART PART NAME...
Page 28
OM-07080 SUPER T SERIES ILLUSTRATION DETAIL A Figure 2. Power Unit Kit PAGE E - 4 MAINTENANCE & REPAIR...
Page 29
SUPER T SERIES OM-07080 PARTS LIST Power Unit Kit ITEM PART PART NAME NUMBER BASE/FUEL TANK ASSY 41553-053 24150 ISUZU DIESEL ENGINE 4LE2T FT4 29223-402 CONTROL PANEL INSTALL KIT 48122-563 LIFTING BAIL KIT 48274-811 LOCK WASHER J10 15991 HEX NUT D10 15991 FLAT WASHER K10 15991...
Page 30
OM-07080 SUPER T SERIES ILLUSTRATION Figure 3. Pump End Assembly PAGE E - 6 MAINTENANCE & REPAIR...
Page 31
SUPER T SERIES OM-07080 PARTS LIST Pump End Assembly ITEM PART NAME PART ITEM PART NAME PART NUMBER NUMBER PUMP CASING SEE NOTE BELOW HEX HEAD CAP SCREW B0804-1/2 15991 REPAIR ROTATING ASSY 44163-347 SUCTION FLANGE 11389 10010 PIPE PLUG P04 15079 CHECK VALVE PIN 11557 17010...
Page 32
OM-07080 SUPER T SERIES ILLUSTRATION SEAL AREA DETAIL DETAIL D DETAIL C Figure 4. Repair Rotating Assembly PAGE E - 8 MAINTENANCE & REPAIR...
Page 33
SUPER T SERIES OM-07080 PARTS LIST Repair Rotating Assembly ITEM PART PART NAME NUMBER IMPELLER 10528 11010 IMPELLER ADJ SHIM SET 37J 17090 CARTRIDGE SEAL ASSEMBLY 46513-151 SEAL PLATE 38272-234 10010 SEAL PLATE GASKET 10959G 20000 OIL SEAL S1352 OIL SEAL S1352 OIL SEAL S1352...
Page 34
OM-07080 SUPER T SERIES ILLUSTRATION 0.00 IN. 0.00 MM Figure 5. Drive Assembly PARTS LIST ITEM PART PART NAME NUMBER COUPLING KIT 48112-005 -BUSHING 24131-496 -COUPLING ASSEMBLY 24391-105 -LOCKWASHER 21171-536 ALTERNATE PARTS: -SOCKET HD CAPSCREW BD0606-1/2 15991 -SOCKET HD CAPSCREW 22644-220 HEX HD CAPSCREW B0605 15991...
Page 35
SUPER T SERIES OM-07080 PUMP AND SEAL DISASSEMBLY pump integrity are compromised by such practices. AND REASSEMBLY Review all SAFETY information in Section A. Follow the instructions on all tags, label and de Before attempting to open or service the cals attached to the pump.
Page 36
OM-07080 SUPER T SERIES Separating Intermediate and Drive Assembly ing away from the unit to prevent injury From Engine during automatic operation. Disconnect the positive battery cable before per (Figure 5) forming any maintenance. Failure to do so may result in serious personal injury. Further disassembly requires separating the pump end and drive assembly from the engine.
Page 37
SUPER T SERIES OM-07080 Loosening Impeller Rotating Assembly Removal (Figure 4) (Figure 4) Remove the hardware (13 and 14, Figure 3) secur ing the rotating assembly to the pump casing. Sep Before attempting to loosen the impeller, remove arate the rotating assembly by pulling straight the seal cavity drain plug (15A) and drain the lubri...
Page 38
OM-07080 SUPER T SERIES Remove the impeller adjusting shims (2); tie and Place a block of wood against the impeller end of tag the shims, or measure and record their thick the shaft and tap the shaft and assembled bear ness for ease of reassembly.
Page 39
SUPER T SERIES OM-07080 The bearing tolerances provide a tight press fit shaft. Position the outboard bearing (22) on the onto the shaft and a snug slip fit into the bearing shaft with the integral retaining ring on the bearing housing.
Page 40
OM-07080 SUPER T SERIES With the lip seal sleeve in place, lubricate the lip Seal Installation seal area of the shaft and slide the shaft and as (Figures 4, 8, 9 and 10) sembled bearings into the bearing housing until the retaining ring on the outboard bearing seats against the bearing housing.
Page 41
SUPER T SERIES OM-07080 RETAINER SEAL PLATE SPRING O‐RINGS IMPELLER SLEEVE O‐RING IMPELLER SHIMS IMPELLER SHAFT INTEGRAL SHAFT ROTATING STATIONARY SLEEVE BELLOWS ELEMENT ELEMENT SHEAR SPRING RING (SHEARED) CENTERING WASHER STATIONARY DRIVE BAND SEAT Figure 8. Cartridge Seal Assembly This seal is not designed for operation at New cartridge seal assemblies may be equipped with mylar storage tabs between temperatures above 160...
Page 42
OM-07080 SUPER T SERIES Continue to screw the impeller onto the shaft. This proper clearance as described in Impeller Instal will press the stationary seat into the seal plate lation and Adjustment. bore. If necessary to reuse an old seal in an emer gency, carefully separate the rotating and station...
Page 43
SUPER T SERIES OM-07080 Slide the rotating portion of the seal (consisting of Rotating Assembly Installation the integral shaft sleeve, spring centering washer, (Figure 3) spring, bellows and retainer, and rotating element) onto the shaft until the seal faces contact. NOTE If the pump has been completely disassembled, it Proceed with Impeller Installation and Adjust...
Page 44
OM-07080 SUPER T SERIES replace the respective gaskets, apply `Permatex just flush with the machined surface on the back Aviation No. 3 Form‐A‐Gasket' or equivalent com side of the cover plate. pound to the mating surfaces, and secure them to Align the back cover plate over the studs (38) and the pump casing with the attaching hardware.
Page 45
SUPER T SERIES OM-07080 Securing Pump End to Engine tion of the coupling with a non‐petroleum based lubricant such as vegetable oil or glycerin, or a sili (Figure 5) con‐based lubricant such as “WD40” or equivalent. Do not use petroleum‐based lubricants, or any oth Install the shaft key (23, Figure 4) in the shaft key...
Page 46
OM-07080 SUPER T SERIES threads. Position the valve as shown in Figure 3 the middle of the sight gauge (14) and maintain it at with the discharge port pointing down. the middle of the gauge. Clean and reinstall the vented plug. Maintain the oil at this level. Final Pump Assembly Bearings (Figure 1)
Page 47
For Warranty Information, Please Visit www.grpumps.com/warranty or call: U.S.: 419-755-1280 Canada: 519-631-2870 International: +1-419-755-1352 GORMAN‐RUPP PUMPS...
Need help?
Do you have a question about the SUPER T T4A60S-4LE2T FT4 Series and is the answer not in the manual?
Questions and answers