Majestic fireplaces WMC36 WMC42 Operating Manual page 14

Wmc series woodburning fireplace
Table of Contents

Advertisement

WMC Series Woodburning Fireplace
Combustible
Mantel and
Trim
(38mm)
12" (305mm)
Min.
Top View
¹⁄₂"
2 x 4 Stud
Finished Wall
Must be sealed with non-
Fireplace Front
combustible material
Fig. 22 Mantel clearance.
FP531b
mantel clearances
9/03 djt
1¹⁄₂"
Ref.
12" from top of grille opening for circulating
* 12" from top of grille opening for circu-
models
lating models
6" from top of grille opening for circulating
** 6" from top of grille opening for circu-
models
lating models
Fig. 23 Combustible mantel clearances.
14
12"
(305mm)
Finished Wall
Max.
Header
1¹⁄₂"
Standoff
Noncombustible
6"
Material
(159mm)
Min.
Grille
Opening
Fireplace
Opening
FP531b
NOTE: No side wall protection is required for fireplaces
installed at 45° to two (2) side walls (corner installation).
Often a decorative surround or vertical portion of the
mantel is desired. If this is constructed of any combus-
tible material it must be within the safe zone indicated in
Figure 23.
Side Wall Protection
Adjacent combustible side walls that are within the mini-
mum dimensions shown in Figure 24 of fireplace open-
ing must be protected with CFM Corporation Wall Shield
Model SP40 or a specifically built wall shield described
below.
The special wall shield design described in Figure 19 is
an alternate method of adding protection to side walls
and can be used in place of the SP40 with the same
wall clearances specified for the SP40. Rt must =1.85
minimum.
Examples of wall shield insulation:
1. Manville - CERAFORM 126, K=.27,
1/2 inches thick
2. CFM Corporation - EH2416, K = .458,
1 inch thick required.
*
Combustible materials are
permitted within a shaded area
shown in Figure 23 titled
Minimum Wall Clearances.
MA81
Face Plate
**
20000583
MA81