8.19

Installing the gas outlet casing

Fig. 56: Installing the gas outlet casing
Part number
51009
Table 45: Tightening torque (51009)
1. Insert a new gasket (61002) into the gas outlet casing (61001).
2. Coat the threads of the studs (51008) with high-temperature grease.
3. Attach the lifting gear to the gas outlet casing (61001) and position the gas outlet casing
in the correct position on the turbine casing (51000).
4. If present: Fit the support (61301).
5. Fit the hexagon nuts (51009). Observe the tightening torque.