TYPE OF GAS

Your natural gas grill is factory built to operate using natural gas only . Never attempt to
operate your grill on gases other than the type specified on the grill rating plates .
Your grill operates at 7" of water column pressure . If replacement of the hose becomes
necessary, factory specified parts are required . See your local dealer .
For safety and design reasons, the conversion of a Weber
Natural gas to operation using LP gas is not allowed .

WHAT IS NATURAL GAS?

Natural gas, often called methane, is a safe modern fuel . Natural gas is supplied by your
local utility and should be readily available if your house is already heated with gas .

NATURAL GAS CONNECTION

Uncoil the NG supply hose and route the end out the access hole at the back panel of
the cabinet (1) . The 330 unit requires a 1/2" hose as opposed to the 3/8" hose for the
310 & 320 . Weber
recommends moving the grill at least 24" from the gas supply and
®
any combustible surfaces . After the gas supply has been run and checked for leaks in
accordance to the assembly instructions, you are ready to grill . To connect the hose
to the gas supply, pull back the outer fitting, insert the hose fitting all of the way, and
release the outer fitting . This process will produce a gas joint .

LEAK CHECK PREPARATION

Check That All Burner Valves Are Off
Valves are shipped in the OFF position, but you should check to be sure that they are
turned off . Check by pushing in and turning clockwise . If they do not turn, they are off . If
they do turn continue turning them clockwise until they stop, then they are off .
Check The Flexible Hose To Manifold Connection
The natural gas hose was attached during the manuafacturing process . We do
recommend that the hose to gas manifold connnection be leak tested, following
guidelines in this Owner's Guide, prior to barbecue operation .
To perform leak checks: Slide back the collar of the quick disconnect (2) . Push male
fitting of the hose into the quick disconnect, and maintain pressure . Slide the collar
closed (3) . If it does not engage or lock, repeat procedure . Gas will not flow unless the
quick disconnect is properly engaged .

GAS INSTRUCTIONS

grill from operation using
®
2
1
2
3
4
Coat this pipe nipple with gas resistant pipe dope
5
6
1
2
3
4
Push plug until sleeve snaps forward locking plug in socket .
(This turns on gas automatically .)
When properly assembled the plug cannot be removed without pushing the sleeve back .
To disconnect, push sleeve back and pull out plug .
(This automatically shuts off gas .)
1
3
Swivel Connection
Install covers when hose is disconnected
Shut Off Valve
Socket
Male Connection
Socket
Sleeve
Push Sleeve Back
Plug
WWW.WEBER.COM
®