Advertisement

Quick Links

HEPA
Filtration*
GSFH1K
VB0061
*Patents pending
INSTALLER: LEAVE THIS MANUAL WITH CONSUMER.
USER MANUAL
HEPA Filtration,
Fresh Air and
Energy Recovery
Ventilation*
GSEH3K
RESIDENTIAL USE ONLY.
REGISTER YOUR PRODUCT ON LINE AT:
For additional information - visit www.Broan.com
HEPA Filtration and
Fresh Air
Ventilation*
GSVH1K
www.broan.com/register
Broan-NuTone LLC
HEPA Filtration,
Fresh Air and
Heat Recovery
Ventilation*
GSHH3K
05690 rev. 5
99043224

Advertisement

Table of Contents
loading

Summary of Contents for Broan GSVH1K

  • Page 1 HEPA Filtration, GSHH3K Fresh Air and *Patents pending Energy Recovery Ventilation* GSEH3K RESIDENTIAL USE ONLY. INSTALLER: LEAVE THIS MANUAL WITH CONSUMER. REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register For additional information - visit www.Broan.com 05690 rev. 5 Broan-NuTone LLC 99043224...
  • Page 2 This will prevent too much humidity from entering the home. To stop the air exchange with a GSVH1K, set its wall controller to OFF. To stop the air exchange with a GSHH3K or a GSEH3K, set its wall controller to RECIRCULATION (the unit will continue to filter the inside air).
  • Page 3: Table Of Contents

    TABLE OF CONTENTS ..........4 BOUT THESE UNITS ............5-8 ONTROLS 2.1 Main Switch..............5 2.2 Operating ACCGSC1 Controller ........5 2.3 Operating 40425 Controller .........6-8 .............9-12 AINTENANCE 3.1 Semi-annual Maintenance .........9-11 3.2 Annual Maintenance .............11 3.3 Optional Alpine/pine Filter..........12 ..........13 ROUBLESHOOTING ............14 ARRANTY - 3 -...
  • Page 4: About These Units

    2. Intended for residential installation in accordance with the requirements of NFPA 90B. 3. For GSVH1K, GSHH3K and GSEH3K units only: Be sure to duct air outside. Do not intake / exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage.
  • Page 5: Controls

    2. CONTROLS 2.1 M WITCH All units are equipped with a 3-position main switch, located on the front panel. The unit is intented for use with a wall controller (provided, see below). The main switch is to remain in either the “OFF” or “Normal/Remote” modes ONLY. The “Normal/Remote” mode allows the homeowner to operate the product from the wall controller (supplied with the unit), typically mounted near a thermostat or other convenient location.
  • Page 6: Operating 40425 Controller

    2. CONTROLS (CONT’D) 2.3 O 40425 C PERATING ONTROLLER The included wall control 40425 is intented for GSHH3K and GSEH3K units only. The wall control is in OFF mode when power is applied for the first time. The mode does not change following a power failure. 2.3.1 40425 C ONTROLLER ESCRIPTION...
  • Page 7 2. CONTROLS (CONT’D) 2.3.2 U 40425 C ’ SING ONTROLLER CONT ECIRCULATION CIRC The unit recirculates air. However, The unit is off. every hour, the unit exchanges The outdoor temperature* air for 6 minutes so that is not displayed. it can obtain a reading of the outdoor temperature*.
  • Page 8 2. CONTROLS (CONT’D) 2.3.3 40425 W ONTROLLER ONFIGURATION See the configuration table below for the list of configuration parameters. Press the Menu button for 3 seconds to enter or exit the configuration menu. NOTE: The wall control automatically saves any changes and exits the configuration menu if no button is pressed within the next 60 seconds.
  • Page 9: Semi-Annual Maintenance

    GSHH3K only), the energy recovery core (model GSEH3K only) and the filter cartridge from the unit. NOTES: 1. On model GSVH1K only, never grab the white shaft (item 2) to pull out the air diffuser. 2. To remove the filter cartridge, pull on its tabs...
  • Page 10 Clean the inside walls of the unit with a clean damp cloth, then wipe with a dry one. Install the new filter cartridge. For HEPA Filtration and Fresh Air Ventilation model GSVH1K only Clean the air diffuser with a clean damp cloth, then wipe with a dry one. Once the air diffuser completely dry, slide it back into the unit.
  • Page 11: Annual Maintenance

    3. MAINTENANCE (CONT’D) 3.1 S ’ ANNUAL AINTENANCE ESSENTIAL CONT For HEPA Filtration, Fresh Air and Energy Recovery model GSEH3K only CAUTION The GSEH3K energy recovery core cannot be washed with water. Slide out the two core filters (item 1) from the energy recovery core and wash them under hot water with mild soap.
  • Page 12: Optional Alpine/Pine Filter

    3. MAINTENANCE (CONT’D) 3.3 O PTIONAL LPINE PINE ILTER During pollen season, or as needed, remove the assembled hood from its backplate by removing its 2 retaining screws. VD0124 screw Then, slide out the optional Alpine/pine filter and clean it under water. Let dry before reinstalling it on the assembled hood.
  • Page 13: Troubleshooting

    Refer servicing to qualified service personnel. If the unit seems not working properly, call your installer or the nearest approved Service Center. You can also reach our Customer Service Departments or Technical Support listed below. Broan-NuTone LLC • Customer Service Department: Telephone: 1-800-558-1711 Fax: 1-800-356-5862 •...
  • Page 14: Warranty

    This warranty gives you specific legal rights and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. In order to qualify for a warranty claim, the owner of a Broan-NuTone WHOLE-HOUSE AIR FILTRATION SYSTEM must have the model and serial number along with a proof of the original purchase date.

This manual is also suitable for:

Gsfh1kGshh3kGseh3k

Table of Contents