4-wire connection: Power supply cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through
the neutral.
1. Remove the ground-link screw from the range frame.
Save the ground-link screw. Bend the ground link away
from the range so that it does not contact the range.
A
A. Ground-link screw
B. Ground link bent away from range
2. Connect the green ground wire from the power supply
cord to the range using the ground-link screw. The ground
wire must be attached first and must not contact any other
terminal.
3. Use a
1
/
" nut driver to remove the hex washer head screws
4
from the terminal blocks.
4. Connect the neutral (center) wire to the center terminal
connector using one of the hex washer head screws.
Securely tighten screw for proper electrical connection.
D
C
B
A
A. Line 1
B. Green ground wire
C. Ground-link screw
D. Hex washer head screw
E. Silver-colored terminal
block screw
5. Connect the other 2 wires (lines 1 and 2) to the outer
aluminum terminal blocks.
6. Securely tighten screws for proper electrical connection.
7. Tighten strain-relief screws.
8. Replace terminal block cover.
B
E
F
G
H
I
F. Ground link
G. Neutral (center) wire
H. Line 2
I. UL Listed strain relief
and 40- or 50-amp range
power supply cord
3-wire connection: Power supply cord
Use this method only if local codes permit connecting cabinet-
ground conductor to neutral wire of power supply cord.
1. Use a
/
" nut driver and remove the hex washer head
1
4
screws from the aluminum terminal blocks.
2. Connect the neutral (center) wire to the center terminal
connector using one of the hex washer head screws.
Securely tighten screw for proper electrical connection.
C
B
A
A. Line 1
B. Ground link
C. Hex washer head screw
D. Silver-colored terminal
block screw
3. Connect the other 2 wires (lines 1 and 2) to the outer
terminal screws on the terminal block.
4. Tighten strain-relief screws.
5. Replace terminal block cover.

Install Water Filtration System

(on some models)
Install Model W10049700 Water Filter
1. Install the water filter near the cold water supply pipe under
the kitchen sink to filter the cold water.
IMPORTANT: Be sure to allow a minimum clearance of
1
/
" (3.8 cm) under the filter system for removing the filter
1
2
cartridge.
Make sure that the water filter assembly is installed in the
upright position.
Typical Installation Configuration
NOTE: For unique installations, contact a licensed plumber.
In Massachusetts, a licensed plumber is required and the
Commonwealth of Massachusetts Plumbing Code 248-CMR
will be adhered to.
Cold water
supply
Hot Cold
D
E
F
G
E. Neutral (center) wire
F. Line 2
G. UL Listed strain relief
and 40- or 50-amp range
power supply cord
Water supply
line to oven
Filter
Assembly
Water supply
line to cold
water supply
15