General Information

Area Requirements
Verify the following:
• Unit can fit into residence and can be moved
around corners and through doorways.
• Floors can support unit's weight plus wine
weight (approximately 1200 lbs total).
• Rear wall is solid and is able to support two
horizontally mounted 50x100 mm (included)
bolted to two wall studs. The 50x100 mm
board bolt heads must be flush with 50x100
mm to prevent obstruction.
• Remove anything attached to rear or side walls
that can obstruct unit installation.
• Cutout dimensions are accurate.
• Electrical outlet is in correct location.
• Do not install a refrigeration unit near a
heat source, nor in a location where the
surrounding temperature will fall below 60º F.
Electrical Requirements
IMPORTANT: If the power cord is damaged, it
must be replaced by a Viking qualified
technician or a Viking Range Corporation
WARNING
ELECTRICAL SHOCK HAZARD
Plug into a grounded 3-prong outlet.
DO NOT remove ground plug.
DO NOT use an adapter.
DO NOT use an extension cord.
Failure to follow these instructions could
result in fire or electrical shock.
representative in order to avoid hazard.
It is the customer's responsibility to:
• Contact a qualified electrical installer.
• Assure that the electrical installation is
adequate and in conformance with all local
codes and ordinances. (127 volt, 60-Hz, 15
amp, fused, electrical supply is required.) It is
required that a separate circuit serving only
this appliance be provided. This appliance is
equipped with a power supply cord having a
3-prong grounding plug. To minimize possible
shock hazard, the cord must be plugged into a
mating 3-prong, grounding-type wall
receptacle. Do not use an extension cord.
If codes permit a separate grounding wire to be
used, it is recommended that a qualified
electrician determine that the grounding path is
adequate.
DO NOT ground to a gas pipe. Check with a
qualified electrician if you are not sure the
appliance is properly grounded.
Do not have a fuse in the neutral or grounding
circuit.
Anti-Tip Requirements
The anti-tip boards should be fastened
into position prior to moving the unit into
the opening.
NOTE: Additional mounting boards may
be required if the unit does not touch
the back wall of the enclosure. To
prevent unit from tipping forward, it
must be secured in place with a solid
soffit or wood block.