Page 1
785 DF So ener System 1. Read all instruc ons carefully before opera on. 2. Avoid pinched O-rings during installa on by applying (provided with install kit) NSF cer fied lubri- cant to all seals. 3. This system is not intended for trea ng water that is microbiologically unsafe or of unknown quality without adequate disinfec on before or a er the system.
Table of Contents PAGE Unpacking / Inspection Safety Guide Proper Installation Specification Before Starting Installation Installation Instructions System Start Up Programming Instructions About The System Maintenance Sanitizing Procedure Main Repair Parts Trouble Shooting Warranty Unpacking / Inspection Be sure to check the entire softener for any shipping damage or parts loss. Also note dam- age to the shipping cartons.
Proper Installation This water softening system must be properly installed and located in accordance with the Installation Instructions before it is used. Do not install or store where it will not be psi, night time pressure may exceed the • exposed to temperatures below freezing or maximum.
Specifications • Continuous operation at flow rates greater than the service flow rate may affect capacity and efficiency performance. • The manufacturer reserves the right to make product improvements which may deviate from the specifications and descriptions stated herein, without obligation to change previously manufactured products or to note the change. Before Starting Installation Tools, Pipe, and Fittings, Other Materials •...
Where To Install The Softener Place the softener as close as possible to is least likely to occur if a leak develops. • the pressure tank (well system) or water The manufacturer will not repair or pay for meter (city water). water damage.
Installation Instructions 1. If your hot water tank is electric, turn off the power to it to avoid damage to the element in the tank. 2. If you have a private well, turn the power off to the pump and then shut off the main wa- ter shut off valve.
System Start-Up Key Pad Configuration SETTINGS This func on is to enter the basic set up infor- ma on required at the me of installa on. MANUAL This func on is to ini ate an immediate or REGEN delayed manual regenera on. DOWN / Increase or decrease the value of the se ngs while in the programming mode.
Programming Instructions TIME DAY, YEAR, For SIM units choose IRON & MONTH, DAY, Time of day is for normal op- eration of system and the WATER TYPE scheduling of the regenera- Select WELL / OTHER if any tion time. The date is used Iron or Manganese is present in a diagnostic function to or if the water source is not...
About The System Control Operation During A Power Failure In the event of a power failure, the valve will keep track of the time and day for 48 hours. The programmed settings are stored in a non-volatile memory and will not be lost during a power failure.
Regeneration Process When the system capacity is near exhausted, a regeneration is necessary to restore the sys- tem to full capacity. The table below explains the regeneration steps. Automatic Hard Water Bypass During Regeneration The regeneration cycle can last 30 to 180 minutes, after which soft water service will be re- stored.
Manual Bypass In the case of emergency, such as an overflowing brine tank, you can isolate your water softener from the water supply using the bypass valve located at the back of the control. In normal operation the bypass is open with the on/off knobs in line with the inlet and outlet pipes.
Page 13
Cleaning or Replacing Injectors Sediment, salt and silt will restrict or clog the injector. A clean water supply and pure salt will prevent this from happening. The injector assembly is located on the right side of the control valve. This assembly is easy to clean.
Page 14
Replacing Brine Line Flow Control (BLFC) TIP: Markings on the BLFC washer should face the direction as shown here. 1. Remove the red clip that secures the brine elbow. 2. Remove the BLFC holder from the elbow fitting. 3. Split the BLFC holder apart and remove the flow washer. 4.
Care of Your System To retain the attractive appearance of your new water softener, clean occasionally with mild soap solution. Do not use abrasive cleaners, ammonia or solvents. Never subject your sof- tener to freezing or to temperatures above 100°F. Resin Cleaner An approved resin cleaner must be used on a regular basis if your water supply contains iron.
Page 16
Brine Tank & Res-Up Feeder Assembly Step 3 Install brine well. Feed wick from feeder into the opening in the brine well cap.
Control Valve Exploded View VALVE REPAIR PARTS LIST Replacement Replacement Part Description Part Description Part Number Part Number 60010127 INJECTOR SET #0000 BLACK 60010129 85HE UPFLOW PISTON ASSEMBLY 60010126 INJECTTOR SET #000 GREY 60010171 85HE DOWNFLOW PISTON ASSEMBLY 60010035 INJECTOR SET #00 VIOLET 60010130 85HE SEAL &...
Warranty Canature WaterGroup warrants that your new water conditioner is built of quality materi- al and workmanship. When properly installed and maintained, it will give years of trouble free service. Seven Year Complete Parts Guarantee Canature WaterGroup will replace any part which fails within 84 months from date of manufacture, as indicated by the serial number, provided the failure is due to a defect in material or workmanship.
Need help?